TROUBLESHOOTING

BDH-450 / BDH-550

TROUBLESHOOTING

Trouble

 

Cause

 

Solution

 

 

 

 

 

 

1.

No power supply.

1.

Plug power cord firmly into outlet and check fuse for that room.

 

2.

Turn the unit on.

 

2.

Unit is not turned on.

The unit does not work.

3.

Set the humidity level on a lower percentage.

3.

Humidity is set higher than the room humidity.

 

4.

If a unit was turned off and turned on automatically the

 

4.

The power was shut off and automatically turned back on.

 

 

compressor will take 5 minutes to start.

 

 

 

 

 

 

 

 

 

Water light is lit.

1. There is blockage of the flow of water in the unit.

1.

Check the hose for crimps or blockage.

2.

Make sure the height of the hose is below 10ft.

 

 

 

 

 

 

 

 

 

1.

Air filter is dirty and or blocked.

1.

Clean the filter.

 

2.

Raise the room temperature.

 

2.

The room temperature is below 40 °F.

The air in the room is still humid.

3.

Improve the airflow by moving unit away from anything that

3.

Poor air circulation or obstructions.

 

 

obstructs the airflow.

 

4.

Humidity is set higher than the room humidity.

 

 

4.

Set the humidity percentage to a lower percentage.

 

 

 

 

 

 

 

 

Relative humidity setting not being reached after

1.

There are windows or doors opened.

1.

Check to see the windows and doors are closed.

a long period of operation.

2.

Area is to large for the capacity of the dehumidifier.

2. Change the location of the dehumidifier with-in room.

 

 

 

 

Defrost light is on.

1.

The temperature in the room is below 40 °F.

1. Raise the room temperature above 40 °F.

2.

Air filter is dirty.

2. Remove and clean the air filter.

 

 

 

 

 

 