2.2.2 DC Power Supply Wiring and Grounding

Figure 5 - DC Power supply wiring and grounding diagram

The RS910L low voltage DC power supply features reverse polarity protection and dual independent inputs. The latter feature allows the connection of two DC sources with the same nominal voltage to provide redundant power supply inputs.

The RS910L DC power supply inputs should be connected as follows:

1.Connect to the DC inputs according to the polarity markings on the unit.

2.Surge Ground should be connected to the Chassis Ground via a braided cable or other appropriate grounding wire. Surge Ground is used as the ground conductor for all surge and transient suppression circuitry internal to the unit.

3.Chassis Ground must be connected to the protective earth.

NOTES:

1.Equipment must be installed according to the applicable country wiring codes.

2.All line-to-ground transient energy is shunted to the Surge Ground terminal. In cases where users require the inputs to be isolated from ground, remove the ground braid between Surge and Chassis Ground. Note that all line-to-ground transient protection circuitry will be disabled.

 

10

2007 RuggedCom Inc. All rights reserved

Rev100

Page 10
Image 10
RuggedCom RS910L manual DC Power Supply Wiring and Grounding, DC Power supply wiring and grounding diagram