5.6 Ethernet Ports

5.6.1 Copper Ports

Parameter

 

Specification

 

Notes

 

 

 

 

 

Speed

 

10/100 Mbps

 

Auto-negotiating

 

 

 

 

 

Duplex

 

FDX / HDX

 

Auto-negotiating

 

 

 

 

 

Cable-Type

 

> Category 5

 

Shielded/Unshielded

Wiring Standard

 

TIA/EIA T568A/B

 

Auto-Crossover, Auto-polarity

Max Distance

 

100 m

 

 

Connector

 

RJ45

 

 

Isolation

 

1.5 kV

 

RMS 1-minute

Table 12: Ethernet Ports - Copper Specifications

5.6.2 Fiber Optic Ports

 

Speed

 

 

Mode /

 

 

Tx λ

 

 

Cable

 

 

Tx Pwr

 

 

Rx

 

 

Rx Saturation

 

 

Typical

 

 

Power

 

 

Standard

 

 

 

 

 

 

Type2

 

 

(dBm peak) 3

 

 

Sensitivity

 

 

 

 

Distance

 

 

Budget

 

 

 

 

Connector

 

 

(nm)

 

 

(dBm Peak) 3

 

 

 

 

 

 

 

 

 

(m)

 

 

(Min / Max)

 

 

(dBm Average) 3

 

 

 

 

(km) 1

 

 

(dB)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100Base-FX

 

MM / ST

1310

 

50/125

 

-15.7

 

-33.5

 

-11

 

2

 

17

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100Base-FX

 

MM / SC

1310

 

50/125

 

-16/-11

 

-33

 

-11

 

2

 

17

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100Base-FX

 

MM / LC

1310

 

50/125

 

-19 / -14

 

-32

 

-14

 

2

 

15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100Base-FX

 

MM / MTRJ

1310

 

50/125

 

-16/-11

 

-33.5

 

-11

 

2

 

17

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100Base-FX

 

SM / ST

1310

 

9/125

 

-15/-8

 

-32

 

-7

 

20

 

16.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100Base-FX

 

SM / SC

1310

 

9/125

 

-13/5

 

-31

 

-4

 

20

 

20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100Base-FX

 

SM / LC

1310

 

9/125

 

-15/-8

 

-31

 

-5

 

15

 

16.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 13: Ethernet Ports – Fiber Optic Specifications

NOTES:

1.Maximum segment length is dependent on factors such as fiber quality, and number of patches and splices. Please consult RuggedCom sales associates when determining maximum segment distances.

2.To convert from average to peak add 3 dBm. To convert from peak to average, subtract 3 dBm.

5.7Communication Standards

Protocol

 

Standards

 

Ethernet

 

IEEE 802.3

 

Table 14 - Communication Standard Compliance

 

 

 

 

25

 

2007 RuggedCom Inc. All rights reserved

Rev100

Page 25
Image 25
RuggedCom RS910L manual Ethernet Ports, Communication Standards