The unit can automatically select the best bit-rate based on current line conditions. If the line conditions degrade (reducing the SNR) but the unit is able to maintain the link, an alarm will be triggered to notify the user of the reduced SNR. If the line conditions degrade such that the unit is unable to maintain the current link, the unit will restart the scan process.

NOTES:

1.This port is designed to be used on private communications lines and is not to be connected to the Public Switched Telephone Network (PSTN).

2.To reduce the risk of fire, use only No. 26 AWG or larger telecommunication line cord.

4.2 RJ45 Ethernet Ports

The RS910L has several 10/100Base-TX ports that allow connection to standard category 5 (CAT-

5)unshielded twisted-pair (UTP) cable with RJ45 male connectors. The RJ45 receptacles are

directly connected to the chassis ground on the unit and can accept CAT-5 shielded twisted-pair (STP) cables. If shielded cables are used, care must be taken to ensure the shielded cables do not form a ground loop via the shield wire and the RJ45 receptacles at either end. The figure below shows the RJ45 port pin-out.

Figure 14 - RJ45 Ethernet port pin-out

 

 

 

 

 

Pin

Signal

 

 

1

+Rx

 

 

2

-Rx

 

 

3

+Tx

 

 

4

No Connection

 

 

5

No Connection

 

 

6

-Tx

 

 

7

No Connection

 

 

8

No Connection

 

 

Case

Shield (Chassis Ground)

 

 

 

 

 

20

2007 RuggedCom Inc. All rights reserved