TROUBLESHOOTING

ENGINE WILL NOT START

C A U S E

A C T I O N

On/Off Stop Control in the STOP position

Turn the On/Off Stop Control to START

Empty fuel tank

Fill fuel tank

Primer bulb wasn't pressed enough

Press primer bulb fully and slowly 5-7 times

Engine flooded

Use starting procedure with choke control in the

 

RUN position, Pg. 12

Old or improperly mixed fuel

Drain fuel tank / Add fresh fuel mixture

Fouled spark plug

Replace or clean the spark plug

ENGINE WILL NOT IDLE

C A U S E

A C T I O N

Air Filter is Plugged

Replace or clean the air filter

Old or improperly mixed fuel

Drain fuel tank / Add fresh fuel mixture

Improper carburetor adjustment

Adjust per instruction Pg. 16

ENGINE WILL NOT ACCELERATE

C A U S E

A C T I O N

Old or improperly mixed fuel

Drain fuel tank / Add fresh fuel mixture

Improper carburetor adjustment

Take to an authorized service dealer for

 

carburetor adjustment

ENGINE LACKS POWER OR STALLS WHEN UNDER LOAD

C A U S E

A C T I O N

Old or improperly mixed fuel

Drain fuel tank / Add fresh fuel mixture

Improper carburetor adjustment

Take to an authorized service dealer for

 

carburetor adjustment

Cultivator tines bound with dirt or grass

Stop the unit, switch the On/Off Stop Control to

 

STOP, clean and remove any debris binding the tines

18

Page 18
Image 18
Ryobi 410r manual Troubleshooting, U S E T I O N