Hitachi Complete Wiring Diagram and Insights for Variable Frequency Drives

Models: X200 Series

1 286
Download 286 pages 46.11 Kb
Page 144
Image 144

45

Example Wiring Diagram

The schematic diagram below provides a general example of logic connector wiring, in addition to basic power and motor wiring converted in Chapter 2. The goal of this chapter is to help you determine the proper connections for the various terminals shown below for your application needs.

Breaker,

 

 

 

 

 

MCCB or GFI

 

X200

 

 

Power source,

 

R

U

 

 

(L1)

 

(T1)

Motor

3-phase or 1-

 

S

 

V

phase, per

 

 

 

 

(L2)

 

(T2)

 

inverter model

 

T

 

W

 

 

 

 

 

 

 

N(L3)

 

(T3)

 

 

 

 

 

PD/+1

DC reactor

Intelligent inputs,

 

 

 

(optional)

5 terminals

P24

+ - 24V

 

 

 

 

P/+

 

 

Forward

 

 

 

NOTE: For the wiring

 

 

 

 

 

1

 

 

 

of intelligent I/O and

 

 

 

Braking

analog inputs, be sure

Reverse

 

 

 

to use twisted pair /

 

2

Input

N/-

unit

shielded cable. Attach

 

(optional)

the shielded wire for

 

 

circuits

 

 

each signal to its

 

3

 

 

 

respective common

 

 

 

 

 

 

 

 

 

terminal at the inverter

 

 

 

 

 

end only.

 

4

 

 

 

 

 

 

AL1

Relay contacts,

 

 

 

 

 

 

5

[5] configurable as

AL0

type 1 Form C

 

 

 

 

 

 

discrete input or

 

Thermistor

 

PLC

thermistor input

AL2

 

 

 

 

 

 

 

L

 

 

 

GND for logic inputs

 

 

 

 

 

 

 

Open collector output

Meter

 

 

Output circuit

11

Freq. arrival signal

 

 

 

 

Load

 

 

AM

 

 

+

Analog reference

 

 

 

-

H

 

CM2

 

 

 

 

GND for logic outputs

0~10VDC

 

 

 

O

 

 

 

 

 

 

 

 

 

4~20mA

OI

 

 

 

 

 

 

 

 

 

 

L

 

 

 

GND for analog signals

 

 

 

Operations and Monitoring

Page 144
Image 144
Hitachi X200 Series instruction manual Example Wiring Diagram, Optional