To prepare to run the motor in the powerup test, this section will show how to configure the necessary parameters:

1.Select the keypad potentiometer as the source of motor speed command (A001).

2.Select the keypad as the source of the RUN command (A002).

3.Set the inverters maximum output frequency to the motor (A003).

4.Set the motor current for proper thermal protection (B012).

5.Set the inverter’s Automatic Voltage Regulation for the motor (A082).

6.Set the number of poles for the motor (H004).

The following series of programming tables are designed for successive use. Each table uses the previous table’s final state as the starting point. Therefore, start with the first and continue programming until the last one. If you get lost or concerned that some of the other parameters setting may be incorrect, refer to “Restoring Factory Default Settings” on page 6-8.

Prepare to Edit Parameters – This sequence begins with powering ON the inverter, then it shows how to navigate to the “A” Group parameters for subsequent settings. You can also refer to the “Keypad Navigation Map” on page 2-26for orientation throughout the steps.

Inverter Mounting and installation

 

 

Action

Display

Func./Parameter

Turn ON the inverter.

 

 

 

Inverter output frequency

 

0.0

 

 

 

Displayed (0Hz in Stop Mode)

 

 

 

 

 

 

Press the

 

key.

 

 

 

“D” Group selected

FUNC

 

d001

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Press the

2

key four times.

 

A- - -

 

“A” Group selected

 

 

 

 

 

 

 

Select the Potentiometer for Speed Command – The inverter output frequency can be set from several sources, including an analog input, memory setting, or the network, for example. The powerup test uses

Potentiometer Enable LED

the keypad potentiometer as the speed control source for your convenience. In the figure to the right, notice the Potentiometer Enable LED, just above the knob. It the LED is ON, the potentiometer is already selected as the source, and you may skip this step. Note that the default setting depends on the country.

STOP

RUN RESET

FUNC 1

Hz POWER

A ALARM

RUN

PRG

2

STR

Page 68