B19

ModBus Data Listing

ModBus Coil List

The following tables list the primary coils for the inverter interface to the network. The table legend is given below.

Coil Number - The network register address offset for the coil. The coil data is a single bit (binary) value.

Name - The functional name of the coil

R/W - The read-only (R) or read-write (R/W) access permitted to the inverter data

Description - The meaning of each of the states of the coils

List of Coil Numbers

 

Coil

Name

R/W

Description

 

 

Number

 

 

 

 

 

 

 

0000h

(Reserved)

R

 

 

0001h

Run command

R/W

0…Stop

 

 

 

 

 

1…Run (enable when A003=03)

 

 

0002h

FW/RV command

R/W

0…RV

 

 

 

 

 

1…FW (enable when A003=03)

 

 

0003h

External trip (EXT)

R/W

0…No trip event

 

 

 

 

 

1…Trip occurred

 

 

0004h

Trip reset (RS)

R/W

0…No reset condition

 

 

 

 

 

1…Reset

 

 

0005h

(Reserved)

R

 

 

0006h

(Reserved)

R

 

 

0007h

Intelligent input terminal 1

R/W

0…OFF *1

 

 

0008h

Intelligent input terminal 2

R/W

1…ON

 

 

0009h

Intelligent input terminal 3

R/W

 

 

 

000Ah

Intelligent input terminal 4

R/W

 

 

 

000Bh

Intelligent input terminal 5

R/W

 

 

 

000Dh

(Not used)

 

 

000Eh

Run/Stop status

R

0…Stop (corresponds to D003 monitor)

 

 

 

 

 

1…Run

 

 

000Fh

FW/RV status

R

0…FW

 

 

 

 

 

1…RV

 

 

0010h

Inverter ready

R

0…Not ready

 

 

 

 

 

1…Ready

 

 

0011h

(Reserved)

R

 

 

0012h

(Reserved)

R

 

 

0013h

(Reserved)

R

 

Appendix B

Page 246
Image 246
Hitachi X200 Series instruction manual ModBus Data Listing, ModBus Coil List, List of Coil Numbers Name Description