330

Add Frequency – The inverter can add or subtract on offset value to the output frequency setting which is specified by A001 (will work with any of the five possible sources). The ADD Frequency is a value you can store in parameter A145. the ADD Frequency is summed with or subtracted from the output frequency setting only when the [ADD] terminal is ON. Function A146 selects whether to add or subtract. By configuring an intelligent input as the [ADD] terminal, your application can selectively apply the fixed value in A145 to offset (positively or negatively) the inverter output frequency in real time.

Configuring Drive Parameters

Keypad potentiometer

Control terminal

Function F001 setting

ModBus network input

Calculate function output

A145 ADD frequency

Intelligent input

A001 Frequency source setting

+

Σ

Output frequency setting

 

+/-

 

 

 

A146

 

 

ADD direction select

[ADD]

 

 

 

 

“A” Function

Run

 

Defaults

Func.

 

Name /

Description

Mode -FE -FU

Units

Code

SRW Display

Edit

(EU)

 

(USA)

A145

ADD frequency

An offset value that is applied to

9

0.0

 

0.0

Hz

 

 

 

the output frequency when the

 

 

 

 

 

 

 

 

[ADD] terminal is ON.

 

 

 

 

 

 

ST-PNT

0000.0Hz

Range is 0.0 to 400.0 Hz

 

 

 

 

 

A146

ADD direction select

Two options:

 

00

 

00

 

 

 

00Plus (adds A145 value to the

 

 

 

 

 

 

 

 

output frequency setting)

 

 

 

 

 

 

 

 

01Minus (subtracts A145 value

 

 

 

 

 

 

 

 

from the output frequency

 

 

 

 

 

 

ADD DIR

PLUS

setting)

 

 

 

 

 

Page 104