Set the Motor Base Frequency – The motor is designed to operate at a specific AC frequency. Most commercial motors are designed for 50/60 Hz operation. First, check the motor specifications. Then follow the steps below to verify the setting or correct it for your motor. DO NOT set it greater than 50/60 Hz unless the motor manufacturer specifically approves operation at the higher frequency.

 

 

Action

Display

Func./Parameter

(Starting point)

 

 

 

Run command source setting

 

A002

 

 

 

 

 

 

 

 

 

 

 

 

 

Press the

 

key once.

 

 

 

Base frequency setting

1

 

A003

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Default value for the base frequency.

 

 

 

 

60.0

 

 

 

 

 

 

US = 60 Hz, Europe = 50 Hz

Press the

FUNC

key.

 

or

 

 

 

 

 

 

 

 

 

 

 

 

50.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Set to your motor specs (your display

Press the

1

or 2 key as needed.

 

60.0

 

 

 

may be different)

 

 

 

 

 

 

 

STR

 

 

 

 

Store parameter, returns to “A”

Press the

key.

 

A003

 

 

 

Group list

 

 

 

 

 

 

Inverter Mounting and installation

CAUTION: If you operate a motor at a frequency higher than the inverter standard default setting (50Hz/60Hz), be sure to check the motor and machine specifications with the respective manufacturer. Only operate the motor at elevated frequencies after getting their approval. Otherwise, there is the danger of equipment damage.

Set the AVR Voltage Setting – The inverter has an Automatic Voltage Regulation (AVR) function. It adjusts the output voltage to match the motor’s nameplate voltage rating. The AVR smoothes out fluctuation in the input power source, but note that it does not boost the voltage in the event of a brown-out. Use the AVR setting (A082) that most closely matches the one for your motor.

200V class: 200 / 215 / 220 / 230 / 240 VAC

400V class: 380 / 400 / 415 / 440 / 460 / 480 VAC

TIP: If you need to scroll through a function or parameter list, press and hold the 1 or

2key to auto-increment through the list.

To set the motor voltage, follow the steps on the following page.