459

Having two motor profiles lets you store two “personalities” for motors in one inverter’s memory. The inverter allows the final selection between the two motor types to be made in the field through the use of an intelligent input terminal function [SET]. This provides an extra level of flexibility needed in particular situations. See the following table.

Parameters for the second motor have a function code of the form x2xx. They appear immediately after the first motor’s parameter in the menu listing order. The following table lists the parameters that have the second parameter register for programming.

 

Function Name

Parameter Codes

 

 

1st motor

2nd motor

 

 

 

 

 

Multi-speed frequency setting

A020

A220

 

 

Acceleration (1) time setting

F002

F202

 

 

Deceleration (1) time setting

F003

F203

 

 

Frequency source setting

A001

A201

 

 

Run command source setting

A002

A202

 

 

Base frequency setting

A003

A203

 

 

Maximum frequency setting

A004

A204

 

 

Multi-speed frequency setting

A020

A220

 

 

Torque boost select

A041

A241

 

 

Manual torque boost value

A042

A242

 

 

Manual torque boost frequency adjustment

A043

A243

 

 

V/f characteristic curve selection

A044

A244

 

 

V/f gain setting

A045

A245

 

 

Frequency upper limit setting

A061

A261

 

 

Frequency lower limit setting

A062

A262

 

 

Acceleration (2) time setting

A092

A292

 

 

Deceleration (2) time setting

A093

A293

 

 

Select method to use Acc2/Dec2

A094

A294

 

 

Acc 1 to Acc 2 frequency transition point

A095

A295

 

 

Dec 1 to Dec 2 frequency transition point

A096

A296

 

 

Level of electronic thermal setting

B012

B212

 

 

Electronic thermal characteristic

B013

B213

 

 

Overload restriction operation mode

B021

B221

 

 

Overload restriction level setting

B022

B222

 

 

Deceleration rate at overload restriction

B023

B223

 

 

Source of overload restriction selection

B028

B228

 

 

Terminal [1] function

C001

C201

 

 

Terminal [2] function

C002

C202

 

 

Terminal [3] function

C003

C203

 

 

Terminal [4] function

C004

C204

 

 

Terminal [5] function

C005

C205

 

 

Overload level setting

C041

C241

 

 

Motor capacity

H003

H203

 

 

Motor poles setting

H004

H204

 

 

Motor stabilization constant

H006

H206

 

 

Motor voltage setting

H007

H207

 

 

 

 

 

 

Inverter Mounting and installation

Page 198
Image 198
Hitachi X200 Series instruction manual Manual torque boost frequency adjustment