Additional Analog Input Settings

Configuring Drive Parameters

Input Range Settings – The parameters in the following table adjust the input characteristics of the analog current input. When using the inputs to command the inverter output frequency, these parameters adjust the starting and ending ranges for the current, as well as the output frequency range. Related characteristic diagrams are located in “Analog Input Settings” on page 3-13.

Analog sampling setting is the value specified in A016.

 

 

“A” Function

Run

Defaults

Func.

Name /

Description

Mode -FE -FU

Units

Code

SRW Display

Edit (EU)

 

(USA)

A101

[OI]-[L] input active range

The output frequency

 

0.0

 

0.0

Hz

 

start frequency

 

corresponding to the analog input

 

 

 

 

 

 

 

 

range starting point,

 

 

 

 

 

 

OI-EXS

0000.0Hz

range is 0.0 to 400.0 Hz

 

 

 

 

 

A102

[OI]-[L] input active range

The output frequency

 

0.0

 

0.0

Hz

 

end frequency

 

corresponding to the current

 

 

 

 

 

 

 

 

input range ending point,

 

 

 

 

 

 

 

 

range is 0.0 to 400.0 Hz

 

 

 

 

 

 

OI-EXE

0000.0Hz

 

 

 

 

 

A103

[OI]-[L] input active range

The starting point (offset) for the

 

0.

 

0.

%

 

start current

 

current input range,

 

 

 

 

 

 

OI-EX%S

00000%

range is 0. to 100.%

 

 

 

 

 

A104

[OI]-[L] input active range

The ending point (offset) for the

 

100.

 

100.

%

 

end voltage

 

current input range,

 

 

 

 

 

 

OI-EX%E

00000%

range is 0. to 100.%

 

 

 

 

 

A105

[OI]-[L] input start frequency

Two options; select codes:

 

01

 

01

 

enable

 

00Use offset (A101 value)

 

 

 

 

 

 

OI-LVL

0Hz

01Use 0Hz

 

 

 

 

 

Refer to parameter A011 to A015 for analog voltage input.

NOTE: You cannot give voltage input and current input ([O] and [OI] input) at the same time on X200 series inverter.