C8

Intelligent Terminal Functions

Appendix C

 

 

“C” Group Parameters

Default Setting

B031

User

 

 

Func.

 

-FE

-FU

 

 

Name

=10

Setting

 

 

Code

(EU)

(USA)

 

 

 

 

 

 

 

C001

Terminal [1] function

00

00

 

 

 

 

C201

Terminal [1] function, 2nd motor

 

 

 

 

 

 

00

00

 

 

 

 

C002

Terminal [2] function

01

01

 

 

 

 

C202

Terminal [2] function, 2nd motor

01

01

 

 

 

 

C003

Terminal [3] function

02

16

 

 

 

 

C203

Terminal [3] function, 2nd motor

02

16

 

 

 

 

C004

Terminal [4] function

03

13

 

 

 

 

C204

Terminal [4] function, 2nd motor

03

13

 

 

 

 

C005

Terminal [5] function

18

18

 

 

 

 

C205

Terminal [5] function, 2nd motor

18

18

 

 

 

 

C011

Terminal [1] active state

00

00

 

 

 

 

C012

Terminal [2] active state

00

00

 

 

 

 

C013

Terminal [3] active state

00

00

 

 

 

 

C014

Terminal [4] active state

00

01

 

 

 

 

C015

Terminal [5] active state

00

00

 

 

 

 

C021

Terminal [11] function

01

01

 

 

 

 

C026

Alarm relay terminal function

05

05

 

 

 

 

C028

[AM] signal selection

00

00

9

 

 

 

C031

Terminal [11] active state

00

00

 

 

 

 

C036

Alarm relay active state

01

01

 

 

 

 

C038

Output mode of low load detection

01

01

9

 

 

 

 

signal

 

 

 

 

 

 

C039

Low load detection level

Rated current for

9

 

 

 

 

 

each inverter model

 

 

 

 

C041

Overload level setting

Rated current for

9

 

 

 

 

 

each inverter model

 

 

 

 

C241

Overload level setting, 2nd motor

Rated current for

9

 

 

 

 

 

each inverter model

 

 

 

 

C042

Frequency arrival setting for

0.0

0.0

9

 

 

 

 

acceleration

 

 

 

 

 

 

C043

Frequency arrival setting for

0.0

0.0

9

 

 

 

 

deceleration

 

 

 

 

 

 

C044

PID deviation level setting

3.0

3.0

9

 

 

 

C052

PID FBV function high limit

100.0

100.0

9

 

 

 

C053

PID FBV function variable low limit

0.0

0.0

9

 

 

 

C070

Selection of OPE / ModBus

02

02

9

 

 

 

C071

Communication speed selection

06

04

9

 

 

 

C072

Node allocation

1.

1.

9

 

 

 

C074

Communication parity selection

00

00

9

 

 

 

C075

Communication stop bit selection

1

1

9

 

 

 

C076

Communication error select

02

02

9

 

 

 

C077

Communication error time-out

0.00

0.00

9

 

 

 

C078

Communication wait time

0.

0.

9

 

 

 

C081

O input span calibration

100.0

100.0

9

 

 

 

C082

OI input span calibration

100.0

100.0

9

 

 

 

 

 

 

 

 

 

 

Page 274
Image 274
Hitachi X200 Series instruction manual Intelligent Terminal Functions