Appendix B

B37

List of Holding Registers

 

Func.

Name

R/W

Description

Network Data

 

 

Code

Reg.

Range

Res.

 

 

 

 

 

 

 

C044

PID deviation level

R/W

Sets the allowable PID loop error

1129h

0 to 1000

0.1 %

 

 

 

setting

 

magnitude (absolute value), SP-PV,

 

 

 

 

 

 

 

 

range is 0.0 to 100%, resolution is

 

 

 

 

 

 

 

 

0.1%

 

 

 

 

 

C052

PID FBV function high

R/W

When the PV exceeds this value,

112Eh

0 to 1000

0.1 %

 

 

 

limit

 

the PID loop turns OFF the PID

 

 

 

 

 

 

 

 

second stage output, range is 0.0 to

 

 

 

 

 

 

 

 

100%

 

 

 

 

 

C053

PID FBV function

R/W

When the PV goes below this value,

112Fh

0 to 1000

0.1 %

 

 

 

variable low limit

 

the PID loop turns ON the PID

 

 

 

 

 

 

 

 

second stage output, range is 0.0 to

 

 

 

 

 

 

 

 

100%

 

 

 

 

 

C070

Selection of OPE /

R/W

Two option codes:

1137h

2, 3

 

 

 

ModBus

 

02OPE or option

 

 

 

 

 

 

 

 

03ModBus (485)

 

 

 

 

 

C071

Communication speed

 

1138h

 

 

 

selection

 

 

 

 

 

 

 

C072

Node allocation

 

1139h

 

 

C074

Communication parity

NOTE: These network settings are

113Bh

 

 

 

selection

 

not accessible to ModBus. Use the

 

 

 

 

 

C075

Communication stop bit

inverter keypad or digital operator

113Ch

 

 

 

selection

 

to edit. Refer to “Network

 

 

 

 

 

C076

Communication error

Communication Settings” on page

113Dh

 

 

 

select

 

3–60.

 

 

 

 

 

C077

Communication error

 

113Eh

 

 

 

time-out

 

 

 

 

 

 

 

C078

Communication wait

 

113Fh

 

 

 

time

 

 

 

 

 

 

 

C081

O input span calibration

R/W

Scale factor between the external

1141h

0 to 2000

0.1 %

 

 

 

 

 

frequency command on terminals

 

 

 

 

 

 

 

 

L–O (voltage input) and the

 

 

 

 

 

 

 

 

frequency output,

 

 

 

 

 

 

 

 

range is 0.0 to 200%

 

 

 

 

 

C082

OI input span calibration

R/W

Scale factor between the external

1142h

0 to 2000

0.1 %

 

 

 

 

 

frequency command on terminals

 

 

 

 

 

 

 

 

L–OI (voltage input) and the

 

 

 

 

 

 

 

 

frequency output,

 

 

 

 

 

 

 

 

range is 0.0 to 200%

 

 

 

 

 

C086

AM offset calibration

R/W

Offset adjustment of AM output.

1145h

0 to 100

0.1 V

 

 

 

 

 

Range is 0.0 to 10.0

 

 

 

 

 

 

 

 

Adjust together with B080 (AM

 

 

 

 

 

 

 

 

gain adjustment)

 

 

 

 

 

C091

Debug mode enable

Displays debug parameters.

 

 

 

 

 

Two option codes:

 

 

 

 

 

 

 

 

00Disable

 

 

 

 

 

 

 

 

01Enable

 

 

 

 

 

C101

Up/Down memory mode

 

Controls speed setpoint for the

1149h

0, 1

 

 

 

selection

 

inverter after power sycle.

 

 

 

 

 

 

 

 

Two option codes:

 

 

 

 

 

 

 

 

00Clear last frequency (return to

 

 

 

 

 

 

 

 

default frequency F001)

 

 

 

 

 

 

 

 

01Keep last frequency adjusted

 

 

 

 

 

 

 

 

by UP/DWN

 

 

 

 

Page 264