B30

Appendix B

List of Holding Registers

 

Func.

Name

R/W

Description

 

Network Data

 

 

 

Code

Reg.

 

Range

 

Res.

 

 

 

 

 

 

 

 

 

A104

[OI]-[L] input active

R/W

The ending point (offset) for the

1084h

 

0 to 100

 

1 %

 

 

 

range end voltage

 

current input range,

 

 

 

 

 

 

 

 

 

 

range is 0. to 100.%

 

 

 

 

 

 

 

A105

[OI]-[L] input start

R/W

Two options; select codes:

1085h

 

0, 1

 

 

 

 

frequency enable

 

00 Use offset (A101 value)

 

 

 

 

 

 

 

 

 

 

01 Use 0Hz

 

 

 

 

 

 

 

A141

A input select for

R/W

Five options:

108Eh

 

0 to 4

 

 

 

 

calculate function

 

00Digital operator

 

 

 

 

 

 

 

 

 

 

01Keypad potentiometer

 

 

 

 

 

 

 

 

 

 

02[O] input

 

 

 

 

 

 

 

 

 

 

03[OI] input

 

 

 

 

 

 

 

 

 

 

04Network variable

 

 

 

 

 

 

 

A142

B input select for

R/W

Five options:

108Fh

 

0 to 4

 

 

 

 

calculate function

 

00Digital operator

 

 

 

 

 

 

 

 

 

 

01Keypad potentiometer

 

 

 

 

 

 

 

 

 

 

02[O] input

 

 

 

 

 

 

 

 

 

 

03[OI] input

 

 

 

 

 

 

 

 

 

 

04Network variable

 

 

 

 

 

 

 

A143

Calculation symbol

R/W

Calculates a value based on the

1090h

 

0, 1, 2

 

 

 

 

 

 

A input source (A141 selects) and

 

 

 

 

 

 

 

 

 

 

B input source (A142 selects).

 

 

 

 

 

 

 

 

 

 

Three options:

 

 

 

 

 

 

 

 

 

 

00ADD (A input + B input)

 

 

 

 

 

 

 

 

 

 

01SUB (A input - B input)

 

 

 

 

 

 

 

 

 

 

02MUL (A input * B input)

 

 

 

 

 

 

 

A145

ADD frequency

R/W

An offset value that is applied to

1091h

 

0 to 4000

 

0.1 Hz

 

 

 

 

 

the output frequency when the

 

 

 

 

 

 

 

 

 

 

[ADD] terminal is ON.

 

 

 

 

 

 

 

 

 

 

Range is 0.0 to 400.0 Hz

 

 

 

 

 

 

 

A146

ADD direction select

R/W

Two options:

1093h

 

0, 1

 

 

 

 

 

 

00Plus (adds A145 value to the

 

 

 

 

 

 

 

 

 

 

output frequency setting)

 

 

 

 

 

 

 

 

 

 

01Minus (subtracts A145 value

 

 

 

 

 

 

 

 

 

 

from the output frequency etting)

 

 

 

 

 

 

 

A151

POT active range start

R/W

The output frequency

1095h

 

0 to 4000

 

0.1 Hz

 

 

 

frequency

 

corresponding to the POT range

 

 

 

 

 

 

 

 

 

 

starting point,

 

 

 

 

 

 

 

 

 

 

range is 0.0 to 400.0 Hz

 

 

 

 

 

 

 

A152

POT input active range

R/W

The output frequency

1097h

 

0 to 4000

 

0.1 Hz

 

 

 

end frequency

 

corresponding to the POT range

 

 

 

 

 

 

 

 

 

 

ending point,

 

 

 

 

 

 

 

 

 

 

range is 0.0 to 400.0 Hz

 

 

 

 

 

 

 

A153

POT input active range

R/W

The starting point (offset) for the

1098h

 

0 to 100

 

1 %

 

 

 

start

 

POT range, range is 0. to 100.%

 

 

 

 

 

 

 

A154

POT input active range

R/W

The ending point (offset) for the

1099h

 

0 to 100

 

1 %

 

 

 

end

 

POT range, range is 0. to 100.%

 

 

 

 

 

 

 

A155

POT input start

R/W

Two options; select codes:

109Ah

 

0, 1

 

 

 

 

frequency enable

 

00Use offset (A151 value)

 

 

 

 

 

 

 

 

 

 

01Use 0Hz

 

 

 

 

 

 

Note 1: When the value is 10000 (100.0 seconds), a value in the second decimal place is ignored. (for A092/A292 and A093/A293).

Page 257
Image 257
Hitachi X200 Series instruction manual OI-L input active Ending point offset for