B29

List of Holding Registers

 

Func.

Name

R/W

Description

 

Network Data

 

 

 

Code

Reg.

 

Range

 

Res.

 

 

 

 

 

 

 

 

 

A092

Acceleration (2) time

R/W

Duration of 2nd segment of

1074h

 

1 to

 

0.1 sec

 

 

(high)

setting

 

acceleration, range is:

 

 

300000

 

 

 

 

A092

 

R/W

0.01 to 3000 sec.

1075h

 

*1

 

 

 

 

(low)

 

 

 

 

 

 

 

 

 

 

A292

Acceleration (2) time

R/W

Duration of 2nd segment of

1519h

 

1 to

 

0.1 sec

 

 

(high)

setting,

 

acceleration, 2nd motor, range is:

 

 

300000

 

 

 

 

A292

2nd motor

R/W

0.01 to 3000 sec.

151Ah

 

*1

 

 

 

 

(low)

 

 

 

 

 

 

 

 

 

 

A093

Deceleration (2) time

R/W

Duration of 2nd segment of

1076h

 

1 to

 

0.1 sec

 

 

(high)

setting

 

deceleration, range is:

 

 

300000

 

 

 

 

A093

 

R/W

0.01 to 3000 sec.

1077h

 

*1

 

 

 

 

(low)

 

 

 

 

 

 

 

 

 

 

A293

Deceleration (2) time

R/W

Duration of 2nd segment of

151Bh

 

1 to

 

0.1 sec

 

 

(high)

setting,

 

deceleration, 2nd motor, range is:

 

 

300000

 

 

 

 

A293

2nd motor

R/W

0.01 to 3000 sec.

151Ch

 

*1

 

 

 

 

(low)

 

 

 

 

 

 

 

 

 

 

A094

Select method to

R/W

Two options for switching from

1078h

 

0, 1

 

 

 

 

switch to Acc2/Dec2

 

1st to 2nd accel/decel:

 

 

 

 

 

 

 

 

profile

 

00 2CH input from terminal

 

 

 

 

 

 

 

 

 

 

01 Transition frequency

 

 

 

 

 

 

 

A294

Select method to

R/W

Two options for switching from

151Dh

 

 

 

 

 

 

 

switch to Acc2/Dec2

 

1st to 2nd accel/decel:

 

 

 

 

 

 

 

 

profile, 2nd motor

 

002CH input from terminal

 

 

 

 

 

 

 

 

 

 

01Transition frequency

 

 

 

 

 

 

 

 

 

 

(2nd motor)

 

 

 

 

 

 

 

A095

Acc1 to Acc2 frequency

R/W

Output frequency at which

107Ah

 

0 to 4000

 

0.1 Hz

 

 

 

transition point

 

Accel1 switches to Accel2, range

 

 

 

 

 

 

 

 

 

 

is 0.0 to 400.0 Hz

 

 

 

 

 

 

 

A295

Acc1 to Acc2 frequency

R/W

Output frequency at which

151Fh

 

 

 

 

 

 

 

transition point, 2nd

 

Accel1 switches to Accel2, 2nd

 

 

 

 

 

 

 

 

motor

 

motor, range is 0.0 to 400.0 Hz

 

 

 

 

 

 

 

A096

Dec1 to Dec2 frequency

R/W

Output frequency at which

107Ch

 

0 to 4000

 

0.1 Hz

 

 

 

transition point

 

Decel1 switches to Decel2, range

 

 

 

 

 

 

 

 

 

 

is 0.0 to 400.0 Hz

 

 

 

 

 

 

 

A296

Dec1 to Dec2 frequency

R/W

Output frequency at which

1521h

 

 

 

 

 

 

 

transition point, 2nd

 

Decel1 switches to Decel2, 2nd

 

 

 

 

 

 

 

 

motor

 

motor, range is 0.0 to 400.0 Hz

 

 

 

 

 

 

 

A097

Acceleration curve

R/W

Set the characteristic curve of

107Dh

 

0, 1

 

 

 

 

selection

 

Acc1 and Acc2, two options:

 

 

 

 

 

 

 

 

 

 

00linear 01S-curve

 

 

 

 

 

 

 

A098

Deceleration curve

R/W

Set the characteristic curve of

107Eh

 

0, 1

 

 

 

 

selection

 

Dec1 and Dec2, two options:

 

 

 

 

 

 

 

 

 

 

00linear 01S-curve

 

 

 

 

 

 

 

A101

[OI]-[L] input active

R/W

The output frequency

1080h

 

0 to 4000

 

0.1 Hz

 

 

 

range start frequency

 

corresponding to the analog

 

 

 

 

 

 

 

 

 

 

input range starting point,

 

 

 

 

 

 

 

 

 

 

range is 0.0 to 400.0 Hz

 

 

 

 

 

 

 

A102

[OI]-[L] input active

R/W

The output frequency

1082h

 

0 to 4000

 

0.1 Hz

 

 

 

range end frequency

 

corresponding to the current

 

 

 

 

 

 

 

 

 

 

input range ending point,

 

 

 

 

 

 

 

 

 

 

range is 0.0 to 400.0 Hz

 

 

 

 

 

 

 

A103

[OI]-[L] input active

R/W

The starting point (offset) for the

1083h

 

0 to 100

 

1 %

 

 

 

range start current

 

current input range,

 

 

 

 

 

 

 

 

 

 

range is 0. to 100.%

 

 

 

 

 

 

Appendix B

Page 256
Image 256
Hitachi X200 Series instruction manual Acceleration 2 time Duration of 2nd segment