CV-M300
7. Mode Setting
Cautions on Mode Setting.
Before making any mode or jumper setting turn the power OFF.
7.1.1. SW1 Switch on the Rear Panel
Factory settings for SW1 are with all 8 switches in OFF position.
OFF = <
ON = >
SW1
OFF ON
1/50 | 1/125 | 1/250 | 1/500 | 1/1000 | 1/2000 | 1/4500 |
1/10,000
Seconds
|
|
| 1 | < | < < < > | > | > > |
|
|
| ||
|
| SHUTTER | 2 | < | < > > < | < | > > |
|
|
| ||
|
|
| 3 | < | > < > < | > | < > |
|
|
| ||
|
| TRIGGER | 4 |
| Normal | < | > External trigger |
|
| |||
|
| ACCUM | 5 |
| Field | < | > Frame |
|
|
| ||
|
| INTERLACE | 6 | Interlaced | < | > |
|
| ||||
Switchno. |
| GAMMA | 7 |
| 1.0 | < | > | 0.45 |
|
|
| |
Swichfunction | 8 |
| Manual < | > |
| Modesetting |
|
| ||||
231 |
| GAIN |
| Auto |
|
| .ON | |||||
ShutterdataMSBtaLSB |
|
| OFF | ReferForshuttertoshutterspeedtableselect7.1.3. | ||||||||
The shutter values are given for a CCIR camera having the factory settings. Shutter values for other | ||||||||||||
setups and EIA cameras can be seen in table 7.1.3. |
|
|
|
|
|
|
|
|
| |||
7.1.2. Table for SW 1 Setting |
|
|
|
|
|
|
|
|
|
| ||
4 |
| Triggerselect |
|
| Normal |
|
|
| Ext.trigger | |||
5 | CCDaccumula |
| Fieldaccumulation |
| Frameaccumulation | |||||||
7 | Gammacorrection |
|
| Gamma=1.0 |
|
|
| Gamma=0.45 | ||||
6 | Scanningsystem |
|
| 2:1interlaced |
|
|
| |||||
8 | Gain |
|
| Manualgain |
|
|
|
| AGCon | |||
|
|
| Shutterspeed(sec.) |
|
| |||||||
FF | FFFFN |
| Normalshutter |
|
| 2250 | Ext.triggershutter | |||||
ON |
| 1/100Off |
|
|
| EIA:1/601/125(CCIR:1/50) | ||||||
ON | ON |
|
|
|
|
| 1/10,000 |
|
| |||
7.1.3. Table for Shutter Time |
|
|
|
|
|
|
|
|
|
| ||
|
| FF |
|
|
|
|
|
| 45 |
|
|
|
- 14 -