Keypad Timeout Option:

Timeout parameter corresponding to the time it takes to validate after all dispense order data has been entered. If the enter button is not pressed within the time allocated, the keypad display goes back to the initial menu, and the input data is erased.

The keypad timeout is between 0 to 255 seconds (0 no timeout) and the default for this feature is 10 seconds

Keypad Timeout

10-

Active keys:

Numeric keys, , ,

Action:

Press Enter key to move to Hose Inactive Timeout Option

Hose Inactive Timeout Option:

Essentially, this is the time the user has to top-off the dispense and completing the automatic batch.

Timeout parameter corresponding to the time that a RF Meter could stay inactive after the reset key has been pressed on the meter.

If the user has not pressed reset on the RF Meter within the timeout period, the RF Meter will transmit the dispense order quantity to the keypad and lockout the RF Meter.

Meter inactive timeout is sent to the RF meter. It’s the meter (ER) that is responsible of tracking this timer.

The meter inactive timeout is set for all RF Meters.

The meter inactive timeout is between 0 to 65534 seconds (0 = no timeout) and the default value is 10 minutes.

Hose Inactive

600

Active keys:

Numeric keys, , ,

Action:

Press Enter key to move to Display Timeout Option

Samson Corporation-Swannanoa, NC 28778 800.311.1047 www.samsoncorporation.com

Page 19
Image 19
Samson 2190 manual Keypad Timeout