Electrical work

AP50M1Series

Using 4poles ELCB(Earth Leakage Circuit Breaker)

1.Remove the cover of electric box on side panel of the outdoor unit.

2.Connect the electric input wires [L1(R), L2(S), L3(T), N] to each terminal [L1(R), L2(S), L3(T), N] of the electric box on the outdoor unit respectively. (Input wires are purchased by the user separately.)

3.Connect the electric wires to each terminal on the indoor and outdoor unit respectively.

Connector

Earth

Indoor unit

Earth

Indoor and outdoor connection wire

Outdoor Unit

Knife switch or

automatic circuit

breaker

ON

R S T N

NFB

Earth

Power cable

(Purchase separately)

Using 3poles ELCB and 2poles ELCB

1.Remove the cover of electric box on side panel of the outdoor unit.

2.Disconnect the connector A(R-L connection) from the outdoor unit.

3.Connect the electric input wires[L1(R), L2(S), L3(T)] to each terminal[L1(R), L2(S), L3(T)] and input wires(N,L) to each terminal(N,L) of the electric box on the outdoor unit respectively. (Input wires are purchased by the user separately.)

4.Connect the electric wires to each terminal on the indoor and outdoor unit respectively.

 

Break connector

 

Indoor unit

 

Outdoor Unit

 

Knife switch or

 

 

automatic circuit

 

 

breaker

Earth

Earth

 

 

 

 

 

NFB

 

 

Earth

 

Indoor and outdoor

Power cable

 

connection wire

 

(Purchase separately)

 

 

36

Mirage_AP50M0@_IBIM_EN_05323A-02.indd 36

2016-05-19 오후 1:27:23

Page 36
Image 36
Samsung AP50M1ANXSG, AP50M0ANXSG manual AP50M1 Series, Using 3poles Elcb and 2poles Elcb