Energy Labeling Information(AC product)
According to Commission Regulation (EU) No 626/2011
A | Supplier's name | - | Samsung Electronics | Samsung Electronics | Samsung Electronics | |
Co., Ltd. | Co., Ltd. | Co., Ltd. | ||||
|
|
| ||||
|
|
|
|
|
| |
B | Model name | - | AR09FSSYAWTN / | AR12FSSYAWTN / | AR18FSSYAWTN / | |
(Indoor/Outdoor) | AR09FSSYAWTX | AR12FSSYAWTX | AR18FSSYAWTX | |||
|
| |||||
|
|
|
|
|
| |
C | Sound Power Level | dBA | 58 / 59 | 60 / 62 | 60 / 65 | |
(Inside/Outside) | ||||||
|
|
|
|
| ||
|
|
|
|
|
| |
D | Refrigerant name1) | - | ||||
E | GWP | - | 1975 | 1975 | 1975 | |
|
|
|
|
|
| |
F | SEER |
| 7.0 | 6.7 | 6.1 | |
|
|
|
|
|
| |
G | Energy efficiency class (SEER) | - | A++ | A++ | A++ | |
|
|
|
|
|
| |
H | QCE2) (cooling season) | kWh/a | 125 | 183 | 287 | |
I | Pdesignc | kW | 2.5 | 3.5 | 5.0 | |
|
|
|
|
|
| |
J | SCOP | - | 4.0 | 4.0 | 3.8 | |
|
|
|
|
|
| |
K | Energy efficiency class (SCOP) | - | A+ | A+ | A | |
|
|
|
|
|
| |
L | QHE3) (heating season) | kWh/a | 868 | 1050 | 1658 | |
M | Other heating seasons | - | Warmer and Colder | Warmer and Colder | X | |
suitable for use | Season | Season | ||||
|
|
| ||||
|
|
|
|
|
| |
N | Pdesignh (Average) | kW | 2.5 | 3.0 | 4.5 | |
|
|
|
|
|
| |
O | elbu(Tj) (Average) | kW | 0 | 0 | 0 | |
|
|
|
|
|
| |
P | Pdesignh (Warmer) | kW | 2.5 | 3.0 | X | |
|
|
|
|
|
| |
Q | elbu(Tj) (Warmer) | kW | 0 | 0 | X | |
|
|
|
|
|
| |
R | Pdesignh (Colder) | kW | 2.5 | 3.0 | X | |
|
|
|
|
|
| |
S | elbu(Tj) (Colder) | kW | 1.82 | 2.22 | X | |
|
|
|
|
|
| |
T | Declared capacity at | kW | 2.5 | 3.0 | 4.5 | |
reference design conditions | ||||||
|
|
|
|
| ||
|
|
|
|
|
| |
U | Assumed backup heating | kW | 0 | 0 | 0 | |
capacity | ||||||
|
|
|
|
| ||
|
|
|
|
|
|
1)Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant fluid with a GWP equal to [xxx].
This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global
warming would be [xxx] times higher than 1 kg of CO2 , over a period of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional.
2)Energy consumption“XYZ”kWh per year, based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
3)Energy consumption“XYZ”kWh per year, based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
2