Step 2.5 Optional: Changing the direction of the drain hose

Drain pan outlet

Rubber cap

Pour water in the direction of arrow.

<Front view>

Direction of the drained water

Step 2.6 Installing and connecting the assembly pipes to the refrigerant pipes (assembly pipe)

Connect indoor and outdoor units with field-supplied copper pipes by means of flare connections. Use insulated seamless refrigeration grade pipe only, (Cu DHP type according to ISO1337), degreased and deoxidized, suitable for operating pressures of at least 4200 kPa and for burst pressure of at least 20700 kPa. Under no circumstances must sanitary type copper pipe be used.

There are 2 refrigerant pipes of different diameters:

The smaller one is for the liquid refrigerant

The larger one is for the gas refrigerant

A short liquid refrigerant pipe and a short gas refrigerant pipe are already fitted to the air conditioner. The connection procedure for the refrigerant pipes varies according to the exit position of each pipe when facing the wall:

Installation

Left

Right

<Side view>

<Front view>

 

Underside

CAUTION

• Make sure that the indoor unit is in upright

position when you pour water to check for leakage.

Rear right or left

 

Make sure that the water does not overflow onto

<Side view>

the electrical part.

 