CAUTION

If you need a pipe longer than specified in piping codes and standards, you must add refrigerant to the pipe. Otherwise, the indoor unit may freeze.

While removing burrs, put the pipe face down to make sure that the burrs do not get in to the pipe.

Step 2.8 Fixing the installation plateYou can install the indoor unit on a wall, window frame, or gypsum board.

WARNING

Make sure that the wall, window frame, or gypsum board can withstand the weight of the indoor unit. If you install the indoor unit in a place where it is not strong enough to withstand the unit's weight, the unit could fall and cause injury.

Liquid service port

 

 

 

Gas service port

<High pressure>

 

 

 

<Low pressure>

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

When fixing the indoor unit on a wall

Fix the installation plate to the wall giving attention to the weight of the indoor unit.

Plastic anchor

20 mm

Wall

 

 

 

 

Correct

 

 

Inclined

Cracked

Uneven

Damaged

 

 

 

thickness

surface

 

 

<Flare nut>

 

 

NOTE

 

 

 

 

• Excessive torque may cause gas leakage. When

Installation

extending the pipe with welding or brazing,

ensure that nitrogen is used during the welding or

brazing process. The joint must be accessible and serviceable.

CAUTION

• Tighten the flare nut at the specified torque. If the flare nut is over-tightened, it may break to cause leakage of refrigerant gas.

42English

 

 

 

 

(Unit : mm)

 

 

 

 

 

 

Model

A

B

C

 

D

✴✴18/24✴✴

38

126

70

 

38

 

 

 

 

 

 

 

Pipe bundle hole: Ø 65 mm

NOTE

If you mount the plate to a concrete wall using plastic anchors, make sure that gaps between the wall and the plate, created by projected anchor, is less than 20 mm.

When fixing the indoor unit on a window frame

1Determine the positions of the wooden uprights to be attached to the window frame.

2Attach the wooden uprights to the window frame giving attention to the weight of the indoor unit.

3Attach the installation plate to the wooden upright using tapping screws.

EN_DB68-06045A-01.indd 42

 

 

2/23/2017 1:08:00 PM