Specifications

Class A (Information Communication equipment for industrial use) : 460UTn-2, 460UTn2-UD2, 460UTn-B

Attention dealers and users. This device is registered for EMC requirements for industrial use (Class A) and can be used in areas other than general households.

Class B(Information Communication equipment for residential use) : 460UT-2, 460UT-B

This device is registered for EMC requirements for home use (Class B). It can be used in all areas. (Class B equipment emits less electromagnetic waves than Class A equipment.)

(USA Only)

Dispose unwanted electronics through an approved recycler. To find the nearest recycling location, go to our website, www.sam- sung.com/recyclingdirect, or call (877) 278 - 0799

PowerSaver

This LCD Display has a built-in power management system called PowerSaver. This system saves energy by switching your LCD Display to low-power mode when it has not been used for a certain amount of time. The LCD Display automatically returns to normal operation when you press a key on the keyboard. For energy conservation, turn your LCD Display OFF when it is not needed, or when leaving it unattended for long periods. The PowerSaver system operates with a VESA DPM compliant video card installed in your computer. Use the software utility installed on your computer to set up this feature.

PowerSaver

 

State

Normal Op-

Power sav-

Power off

Power off

 

 

 

eration

ing mode

 

(Power

 

 

 

 

 

 

 

 

 

 

 

 

Swich)

Power Indicator

On

Blinking

Amber

Off

 

 

 

 

 

 

 

 

 

460UTn-2

300 Watts

5 Watts

5 Watts

0 Watts

Power Con- 460UTn2-

 

 

 

 

sumption

 

UD2

 

 

 

 

(Typical)

 

460UT-2

230 Watts

2 Watts

1 Watts

0 Watts

 

 

 

 

 

 

 

460UTn-B

260 Watts

5 Watts

5 Watts

0 Watts

 

 

 

 

 

 

 

 

 

 

 

460UT-B

195 Watts

2 Watts

1 Watts

0 Watts

 

 

 

 

 

 

 

Note

The actual power consumption may be different from the indicated power consumption above if the system conditions or settings are changed.

To stop any power consumption, turn off the switch or disconnect the power cable on the back. Be sure to disconnect the power if you intend to stay away from home for many hours.

If you connect a network box (sold separately), the LFD will no longer be in compliance with Energy Star 5.0.