Samsung ML-1210, ML-1200 specifications How to use DCU, DCU Setup, Code

Models: ML-1200 ML-1210

1 80
Download 80 pages 54.05 Kb
Page 15
Image 15

Troubleshooting

4-1 How to use DCU

4-1-1 DCU Setup

You can examine the malfunction of the printer. To perform DCU, open the front discharge cover and leave the connect the harness wire(10 pin/4 pin) to the CN10(4 pin) of the Main control board.

4-1-2 Code

Connect DCU to the printer and turn the power on. It show 7 LED on the panel and each code tells the function of the printer.

Normal Code

While printing or warming up, it indicate the position of the paper

61

Warm up

The printer is on, the cover is open or close.

00-05

Ready(kind of paper)

The printer is ready, the paper is detected when the first paper is printed.

 

 

00: Legal , 01: Letter , 02: A4 , 03: EXEC , 04: B5 , 05: Folio

20

Print Start

The engine controller received the print order from the video controller.

30

Feed Sensor On

The paper is passing out of the Feed Sensor.

40

Feed Sensor off

The paper has passed out of the Feed Sensor.

50

Paper Out

The paper has passed out of Exit Sensor.

69

Sleep Mode

The fuser power turned off to minimize the power consumption.

 

 

 

Error Code

When detecting the malfunction, the printing is stopped to indicate error code.

60, 62, 68

Fuser Error

The error in the fuser occurred. There is a short circuit in the thermistor and the

 

 

thermostat while printing, Low Temperature Error occurs.

 

 

• 60: Open Fuser Error

 

 

• 62: Low Heat Error

 

 

• 68: Over Heat Error

64

Cover Open

The Printer Cover is open or Toner Cartridge not installed.

70

No Paper

No paper in the paper cassette.

71

Paper Jam 0

The front part of paper is jammed between pickup unit and Feed sensor.

72

Paper Jam 1

The front part of paper is jammed between the Discharge sensor and Feed sensor.

73

Paper Jam 2

The front part of paper is jammed just after passing through the discharge sensor.

95

LSU Not Ready

LSU Scanner Motor not ready or Hsync signal not output.

 

 

 

4-2

Samsung Electronics

Page 15
Image 15
Samsung ML-1210, ML-1200 specifications How to use DCU, DCU Setup, Code