Troubleshooting

4-1-3 Self Diagnostic Mode

If Error code occurs due to malfunction of the printer, perform Self Diagnostic Mode to solve the problem.

The printer works only in the self-test mode to solve the malfunction problem.

To enter the self-test mode, turn the power on pressing the buttons of [Down], [Shift] and [Stop] at the same time. Release the button within 2 or 3 seconds if 78 shows in the DCU. If 00 shows in the DCU, press the button [Up] or [Shift] to select the self+test , and press the button of [Enter] to operate. To stop, press the button of [shift] and [Enter] together.

00Main Motor Operating System Only the main motor is in operation.

01

Main High Voltage On(THV-)

 

 

-1550 voltage output by MHV terminal.

Caution : High voltage probe should be used.

 

 

 

02

Transfer High Voltage(-)On(THV-)

 

 

-1300 voltage output by MHV terminal.

Caution : High voltage probe should be used.

 

 

 

03

Transfer High Voltage (+)Reference on (THV +)

 

 

1300 voltage output by MHV terminal.

Caution : High voltage probe should be used.

 

 

04

DEV/supply High Voltage : DEV/Supply High Voltage Test.

 

The left one of the three LEDs in the self-test panel is on when DEV high voltage Supply high voltage output

 

by each HV terminal. Press the [Up] button to switch the voltage. The middle and right one of the three LEDs

 

are on and -530 voltage output by DEV HV terminal.

Caution : High voltage probe should be used.

 

 

 

05

LSU Operating System

 

 

The scanning motor of LSU is in operation, the right LED of the three buttons on. Press the [Up] button to

 

Check LD. LD is functioning and the middle button is on. If the LD is normal, all LEDs are on.

06Pickup clutch on

The Solenoid in the printer is in operation. To stop the operation, Press the button [shift] and [Enter] together.

07

Pempty/PWIDTH/New CRU Sensor Test : Pempty/PWIDTH.HEW CRU sensor test.

 

If activate the Actuator of the PEMPTY/PWIDTH Sensor, the left and right of the three LEDs are on.

 

If you install new toner Cartridge in this mode, the right LED is on.

08Feed & Exit Sensor Test

Test the Feed sensor and Discharge sensor in the same way as '06'.

09Cover Open Sensor Test The same way as code '06'.

10Fuser Test

If the [Enter] button pressed, the right LED is on and temperature of the fuser is up to READY Mode. If the [Up] button pressed, the middle LED is on and temperature of the fuser is up to Printing Mode.

If you press the button once more, the left LED is on and temperature of the fuser is up to overheat Mode.

11Hot Burn Test

If the [enter] button pressed, the printer is continuously printing without detection. Turn the power off to stop operation.

12.Cleaning Mode Print Mode

Print the paper to clean the OPC Drum in the Cartridge.