5-11) OPTION Circuit

OPERATION PRINCIPLES BY PARTS OF CIRCUIT

5-11) OPTION Circuit

This circuit operates with the initial power on, uses DIODE (1N4148) or JUMPER WIRE.

To modify option circuit, Power must be turned off before modification and turned on after the modification. Refer to the table below, the default factory values are highly recommended unless exceptional cases.

OP11, OP12

OP11

 

OP12

MODEL

FUNTION

 

 

 

 

 

 

RS2*11

No Cruch, 3 Step, Light

 

RS2*21

Cruch, 3 Step, Light

 

RS2*31

Cruch, 5 Step, P/F, L/T Lock, Filter, Indicator

* Jumper USE

OP2 < Water Fill Time Control Option >

 

 

 

 

 

 

D601

 

D602

Fill Time

Remark

 

 

 

 

 

 

5 Sec

 

 

 

 

 

 

 

6 Sec

Flow Sensor Not USE

 

 

 

 

 

7 Sec

 

 

 

 

 

 

 

 

10 Sec

 

 

 

 

 

* Diode(1N4148) USE

 

 