4.Determine the type of power supply and set the POWER SELECTION switch accordingly. Next, plug the power adapter into a wall outlet.
5.If the camera operates normally, the following screen will be displayed for 5 seconds and then disappears.
TYPE | 4_ZOM_WDR_P |
PROTOCOL | SAMSUNG |
ADDRESS | 0 |
COMM.TYPE | RS485,HALF |
BAUD RATE | 9600 |
CAMERA VER. | V1.00_090817 |
LENS | OK |
6.The requirements for RS485 control is as follows :
-Signaling Speed: 9600 bps
-Data Bit : 8 bits
-Stop Bit : 1 bit
-Parity Bit : none
14_ installation & connection