Image 9

Connection

Connecting to connection

 

 

External Control Connector

 

GND

 

 

 

MD

 

 

 

COM

 

 

 

FOCUS

 

 

 

ZOOM

Connector

Function

Signal Level

I/O

 

Tele

+6V~+12V

 

ZOOM

COM

I

 

 

 

 

Wide

COM

 

 

-6V~-12V

 

 

 

 

 

Far

+6V~+12V

 

FOCUS

COM

I

 

 

 

Near

COM

 

 

-6V~-12V

 

COM

 

COM

-

 

 

+4.0V~+5.0V

 

MD

 

There is motion

O

0V

5±0.5sec

 

There is no motion

 

 

*MD (Motion Detection) Output Signal Level (less than 10mA)

*When using the MD function, the 'GND' should be connected to the frame ground.

Communication Control Connector

The camera can be controlled by using external controllers like a Remote controller. (RS-485 Communication)

SCC-3000

Remote Controller

6-Pin Connection

 

SCC-100

Cable

* Communication Control Connector Pin Description .

Number

Name

Description

Number

Name

Description

 

 

 

 

 

 

1

GND

-

4

TRX +

RS-485 Communication

 

 

 

 

 

 

2

EXT.SYNC

External ‘SYNC’ Signal

5

TRX -

RS-485 Communication

 

 

 

 

 

 

3

GND

-

6

Output Power

Remote Controller only

 

 

 

 

 

 

* EXT. SYNC

 

3V or 5V

 

Min: 500ns

0V

 

 

 

60Hz ± 0.1Hz(NTSC), 50Hz ± 0.1Hz(PAL)

*Communication Setting can set the communication setting as shown in the table below. When you use to connect SCC-100 or SCC-3000, the default sets for SCC-3000

ITEM

SCC-100

SCC-3000

MODE

Serial

Serial

Data Bit

8 bit

8 bit

Bit/Sec

9600bps

9600bps

Parity

EVEN

NONE

CAM ID NO.

0

1~255

RETURN PACKET

ENABLE

See the SCC-3000 manual

 

 

 

Notes

• Contact an authorized technician for inspection.