To set an alarm input

1 Click <EVENT> <ALARM INPUT 1> or <ALARM INPUT 2>.

The ALARM INPUT window appears.

2 To complete the setting, click the [Apply] button.

The settings are saved.

<Input Device Setup>: Select an input type from the <OFF>, <NO> and <NC>.

-<NO>(Normal Open): It is normally open, but if it is close, an alarm will be generated.

-<NC>(Normal Close): It is normally close, but if it is open, an alarm will be generated.

<Activation Time>: You can set time to accept an alarm to take an action.

-<Always>: Always conducts the <Action> setting when an alarm is generated.

-<Only Scheduled Time>: Conducts the <Action> setting for an alarm only when it occurs during the specified time period on the specified day of the week. The Start Time must prior to and must differ from the End Time.

<Action>: You can set an operation to be conducted when an alarm is generated.

-<Alarm Output>: Determines alarm output port to which the alarm signal is to be sent.

-<Output Duration>: Determines the period of time to output alarm signal to the specified alarm output port when an alarm is generated. If another alarm event is generated during the alarm output, the delay time is recalculated on the basis of the most recently generated an alarm.

-<Alarm Image Transfer>: If <On> is selected, a JPG image is transmitted through FTP or Email (SMTP) or saved on the SDHC memory card according to the <EVENT>

<TRANSFER SETUP> settings.

UP SETTING 07

Setting Up _71