Lamp Replacement Procedure
1.The lamp is very hot and operates with a high voltage. Allow it to cool down for at least 1 hour after disconnecting the power cord before changing the lamp.
2.The lamp is located at the bottom of the product.
Place the product so that its bottom looks upward and remove the screws that hold the lamp cover in place.
*When placing the product with the bottom upwards, make sure to place a soft cloth on the surface to prevent scratches.
3.Slide and open the cover in the direction of the arrow, as shown in the figure.
4.Remove the screws indicated in the figure.
5.Hold and pull the lamp handle slightly, as shown in the figure.
Inserting a new lamp is in the reverse order of the removal.
Installation and Connection |