QUICK GUIDE

Reader Connection

Reader #4

Reader #3

Reader #2

GND

D1

D0

DC+12V

Reader #1

-Connect the plus (+) line of the reader to the corresponding port (DC +12V).

-Connect the minus (-) line of the reader to the GND (-) port.

-Connect the data 0 line of the reader to its port data 0 (D0).

-Connect the data 1 line of the reader to its port data 1 (D1).

 

Door Number

External Reader

Internal Reader

Exit Button

 

 

 

 

 

Two Door Control

1

Reader #1

Reader #2

None

 

 

 

 

2

Reader #3

Reader #4

None

 

 

 

 

 

 

 

1

Reader #1

Reader #2

None

Three Door Control

 

 

 

 

2

Reader #3

None

Internal Exit Button

 

 

 

 

 

 

3

Reader #4

None

Internal Exit Button

 

 

 

 

 

 

1

Reader #1

None

Internal Exit Button

 

 

 

 

 

Four Door Control

2

Reader #2

None

Internal Exit Button

 

 

 

 

3

Reader #3

None

Internal Exit Button

 

 

 

 

 

 

 

4

Reader #4

None

Internal Exit Button

 

 

 

 

 

Refer to the list of compatible readers.

-SSA-P400(T) : 26Bit Wiegand Reader

-SSA-P401(T) : 34Bit Wiegand Reader

ENG

English_7

Page 7
Image 7
Samsung SSA-P400T/EXP, SSA-P400/EXP manual Reader Connection, Door Number, Exit Button