Control Codes

Viewing control state (Get control command)

Header

Command

ID

Data length

Checksum

 

 

 

 

 

0xAA

Command type

 

0

 

Controlling (Set control command)

Header

Command

ID

Data length

Data

Checksum

 

 

 

 

 

 

0xAA

Command type

 

1

Value

 

Command

No.

Command type

Command

Value range

 

 

 

 

1

Power control

0x11

0~1

 

 

 

 

2

Volume control

0x12

0~100

 

 

 

 

3

Input source control

0x14

-

 

 

 

 

4

Screen mode control

0x18

-

 

 

 

 

5

Screen size control

0x19

0~255

 

 

 

 

6

PIP on/off control

0x3C

0~1

 

 

 

 

7

Auto adjustment control (PC and

0x3D

0

 

BNC only)

 

 

 

 

 

 

8

Video wall mode control

0x5C

0~1

 

 

 

 

9

Safety Lock

0x5D

0~1

No.

Command type

Command

Value range

 

 

 

 

10

Video Wall On

0x84

0~1

 

 

 

 

11

Video Wall User Control

0x89

-

•• All communications take place in hexadecimals. The checksum is calculated by adding up all values except the header. If a checksum adds up to be more than 2 digits as shown below (11+FF+01+01=112), the first digit is removed.

E.g. Power On & ID=0

Header

Command

ID

Data length

Data 1

Checksum

 

 

 

 

 

 

0xAA

0x11

 

1

"Power"

 

 

 

 

 

 

 

 

 

 

 

 

 

Header

Command

ID

Data length

Data 1

12

 

 

 

 

 

 

0xAA

0x11

 

1

1

 

•• To control all devices connected by a serial cable simultaneously irrespective of IDs, set the ID as "0xFE" and transmit commands. Commands will be executed by each device but ACK will not respond.

33

Page 33
Image 33
Samsung UE46C, UE55C Control Codes, Viewing control state Get control command, Controlling Set control command, Command