360 Herndon Parkway Suite 1400 Herndon, VA 20170 http://www.rheintech.com

5.3RADIATED EMISSIONS TEST DATA

 

 

 

Temperature: 48°F

Humidity: 36%

 

 

 

 

 

Emission

Test

Antenna

Turntable

Antenna

Analyzer

 

Site

 

Emission

 

 

Pass/

 

Frequency

Detector

Polarity

Azimuth

Height

Reading

 

Correction

 

Level

Limit

Margin

Fail

 

(MHz)

 

(H/V)

(deg)

(m)

(dBuV)

 

Factor

 

(dBuV/m)

(dBuV/m)

(dB)

 

 

 

 

 

 

 

 

 

(dB/m)

 

 

 

 

 

 

50.000

Qp

H

200

3.0

38.4

 

-22.2

 

16.2

30.0

-13.8

Pass

 

73.800

Qp

V

100

1.0

41.6

 

-23.5

 

18.1

30.0

-11.9

Pass

 

144.000

Qp

V

5

1.0

40.1

 

-18.5

 

21.6

30.0

-8.4

Pass

 

191.992

Qp

V

80

1.0

42.2

 

-19.4

 

22.8

30.0

-7.2

Pass

 

200.000

Qp

V

190

1.0

35.3

 

-19.0

 

16.3

30.0

-13.7

Pass

 

225.000

Qp

V

290

1.0

32.7

 

-18.5

 

14.2

30.0

-15.8

Pass

 

250.000

Qp

H

160

4.0

44.2

 

-15.5

 

28.7

37.0

-8.3

Pass

 

369.340

Qp

H

190

1.5

42.8

 

-12.1

 

30.7

37.0

-6.3

Pass

 

406.340

Qp

V

270

1.0

32.9

 

-10.5

 

22.4

37.0

-14.6

Pass

 

463.850

Qp

H

75

2.5

38.8

 

-9.5

 

29.3

37.0

-7.7

Pass

 

485.970

Qp

V

190

1.0

29.4

 

-8.9

 

20.5

37.0

-16.5

Pass

 

631.945

Qp

V

45

1.0

30.8

 

-6.2

 

24.6

37.0

-12.4

Pass

 

700.000

Qp

V

5

1.0

30.4

 

-5.8

 

24.6

37.0

-12.4

Pass

 

Note:

The EUT was scanned from 30 MHz to 15,000 MHz. All emissions other than those listed in the tables above were found to have amplitudes attenuated by more than 20dB below the FCC limit.

Result: Pass

Test Personnel:

 

 

Jon Wilson

 

April 10, 2007

EMC Test Engineer

Signature

Date Of Test

SanDisk Corporation

Page 14 of 17

DoC Report

 

2006137

 

04/27/07

 

Page 14
Image 14