360 Herndon Parkway Suite 1400 Herndon, VA 20170 http://www.rheintech.com
5.3RADIATED EMISSIONS TEST DATA
|
|
| Temperature: 48°F | Humidity: 36% |
|
|
|
|
| ||||
Emission | Test | Antenna | Turntable | Antenna | Analyzer |
| Site |
| Emission |
|
| Pass/ |
|
Frequency | Detector | Polarity | Azimuth | Height | Reading |
| Correction |
| Level | Limit | Margin | Fail |
|
(MHz) |
| (H/V) | (deg) | (m) | (dBuV) |
| Factor |
| (dBuV/m) | (dBuV/m) | (dB) |
|
|
|
|
|
|
|
|
| (dB/m) |
|
|
|
|
|
|
50.000 | Qp | H | 200 | 3.0 | 38.4 |
|
| 16.2 | 30.0 | Pass |
| ||
73.800 | Qp | V | 100 | 1.0 | 41.6 |
|
| 18.1 | 30.0 | Pass |
| ||
144.000 | Qp | V | 5 | 1.0 | 40.1 |
|
| 21.6 | 30.0 | Pass |
| ||
191.992 | Qp | V | 80 | 1.0 | 42.2 |
|
| 22.8 | 30.0 | Pass |
| ||
200.000 | Qp | V | 190 | 1.0 | 35.3 |
|
| 16.3 | 30.0 | Pass |
| ||
225.000 | Qp | V | 290 | 1.0 | 32.7 |
|
| 14.2 | 30.0 | Pass |
| ||
250.000 | Qp | H | 160 | 4.0 | 44.2 |
|
| 28.7 | 37.0 | Pass |
| ||
369.340 | Qp | H | 190 | 1.5 | 42.8 |
|
| 30.7 | 37.0 | Pass |
| ||
406.340 | Qp | V | 270 | 1.0 | 32.9 |
|
| 22.4 | 37.0 | Pass |
| ||
463.850 | Qp | H | 75 | 2.5 | 38.8 |
|
| 29.3 | 37.0 | Pass |
| ||
485.970 | Qp | V | 190 | 1.0 | 29.4 |
|
| 20.5 | 37.0 | Pass |
| ||
631.945 | Qp | V | 45 | 1.0 | 30.8 |
|
| 24.6 | 37.0 | Pass |
| ||
700.000 | Qp | V | 5 | 1.0 | 30.4 |
|
| 24.6 | 37.0 | Pass |
|
Note:
The EUT was scanned from 30 MHz to 15,000 MHz. All emissions other than those listed in the tables above were found to have amplitudes attenuated by more than 20dB below the FCC limit.
Result: Pass
Test Personnel: |
|
|
Jon Wilson |
| April 10, 2007 |
EMC Test Engineer | Signature | Date Of Test |
SanDisk Corporation | Page 14 of 17 |
DoC Report |
|
2006137 |
|
04/27/07 |
|