Brush Roll

Brush Roll

Headlight Bulb (Standard on most models)

The rotating brush roll sweeps and combs the carpet nap. Keep the brush roll free from hair and threads so it will continue brushing. When the bristles of the brush roll no longer touch a straight edge held across the bottom plate, the brush roll is ineffective because the bristles no longer touch the carpet nap. To maintain the most effective cleaning, replace the wood brush roll. Install new brush strips on the chromed steel brush roll (refer to instructions).

How To Replace Worn Brush Strips, PN 52282-4

(chromed steel brush roll)

CAUTION: Turn off the switch and unplug the electrical cord before replacing brush strips.

New brush strips are supplied in sets of two, one long and one short. To replace, remove bottom plate and belt (see How To Change Belt). Then, grasp center of brush roll and lift to remove.

 

 

 

 

G

 

 

 

 

 

F

 

A

B

C

D

E

 

Note:

 

 

 

 

E

Shaft washer (D) not included in ball bearing brush roll assembly.

CAUTION : Turn off the switch and unplug the electrical cord before replacing headlight bulb.

Headlight style varies by model. Locate the notches that release the tabs at either (1) top, (2) side, or (3) bottom of the lens, as illustrated. Place a screwdriver into one notch; twist or pry the screwdriver to release the lens. Repeat for the second notch on the opposite side.

Rotate the bulb socket forward. Push bulb in and turn to remove. Secure new bulb into socket and rotate bulb socket backward.

Replace the lens tabs into the top or the bottom of the hood opening. Rotate lens to position and press down at each notch until the lens locks into position.

CAUTION: Use 25 watt replacement bulb, only.

Ask for GENUINE EUREKA replacement bulb, 40009A.

1

2

3

A.Remove rubber end cap cover (available on select models) from one end.

B.Unscrew locknut.

C.Remove end cap.

D.Remove shaft washer (not included in ball bearing brush roll).

E.Remove bearing retainer.

F.Push shaft through opposite end.

G.Pull out worn brush strip with pliers.

G. Slide in new brush strip of same length (rounded end fi rst). Fit track on either side into brush roll slot. Replace second brush strip from opposite end of brush roll.

F. Replace shaft.

E.Align indentation on bearing retainer with brush strip on both ends of brush roll.

D. Replace shaft washer.

C. Position end cap with flat sides of center hole over flat sides of threaded shaft.

B. Tighten locknut.

A. Align holes and secure rubber end cap cover flat side against end

cap.

Cleaner Care

CAUTION : Turn off the switch and unplug the electrical cord before cleaning unit.

To keep the vacuum cleaner looking new, it can be wiped with a damp cloth and a mild soap solution, then thoroughly dried. Never use any type of chemical as chemicals can damage the cleaner. When not in use, the cleaner should be stored in a clean, dry place.

When properly assembled, the brush roll should rotate freely between the two end caps. Check the condition of the belt; change if necessary. Replace the brush roll, belt, and bottom plate (see How To Replace A Worn Belt).

Ask for GENUINE EUREKA replacement brush strip. 12 inch No. 52282-4.