Sanyo C1852, C1251 How to connect wiring to the terminal, a For Indoor Unit, b For Outdoor Unit

Models: C0951 CL1251 CL1852 CL0951 C1251 C1852

1 22
Download 22 pages 63.33 Kb
Page 12
Image 12
How to connect wiring to the terminal

WARNING Loose wiring may cause the termi- nal to overheat or result in unit mal-

function. A fire hazard may also exist. Therefore, be sure all wiring is tightly connected.

When connecting each power wire to the corresponding termi- nal, follow the instructions “How to connect wiring to the termi- nal” and fasten the wire securely tight with the fixing screw of the terminal plate.

How to connect wiring to the terminal

a) For Indoor Unit

(1)Cut the wire end with a cutting pliers, then strip the insu- lation to expose the wire about 9/32 in. (7 mm). See the label (Fig. 28) near the terminal plate.

(2)Using a screwdriver, loosen the terminal screw on the ter- minal plate.

(3)Insert the wire and tighten the terminal screw completely using a screwdriver.

STRIP

9/32" (7 mm) (ACTUAL

SIZE

SIZE)

 

Fig. 28

mm)

Solid wire

Strip 15/16" (25

Loop

Insulation

 

Fig. 29

b) For Outdoor Unit

For solid core wiring (or F-cable)

(1)Cut the wire end with a cutting pliers, then strip the insu- lation to expose the solid wire about 15/16 in. (25 mm). (Fig. 29)

(2)Using a screwdriver, remove the terminal screw(s) on the terminal plate.

(3)Using the pliers, bend the solid wire to form a loop suit- able for the terminal screw.

(4)Shape the loop wire properly, place it on the terminal plate and fix it securely with the removed terminal screw using a screwdriver.

For stranded wiring

(1)Cut the wire end with a cutting pliers, then strip the insu- lation to expose the stranded wiring about 3/8 in. (10 mm) and tightly twist the wire ends. (Figs. 30 and 31)

Special

(2) Using a screwdriver, remove the terminal screw(s) on the washer terminal plate.

(3) Using a ring connector fastener or pliers, securely clamp

 

each stripped wire end with a ring connector. (Fig. 30)

Wire

(4)Place the ring connector wire, and replace and tighten the removed terminal screw using a screwdriver. (Fig. 32)

Stranded wire mm)(10 a) For Indoor Unitb) For Outdoor Unit

3/8"Strip

Fig. 30

Twist wire ends

Fig. 31

Screw

Ring connector

Terminal plate

Wire

Fig. 32

Ring

Connector

Screw and special washer

Ring connector

12

Page 12
Image 12