Sanyo CL1872 Electrical Data, Electrical Characteristics, Indoor Unit, KS1872, Outdoor Unit

Models: CL1872 CL2472 C1872 C2472

1 88
Download 88 pages 39.38 Kb
Page 31
Image 31

6. ELECTRICAL DATA

6-1. Electrical Characteristics

Indoor Unit

KS1872

 

 

 

 

Outdoor Unit

C1872

 

 

 

 

Cooling

 

 

 

 

 

 

< 230V >

 

 

 

 

 

 

 

 

 

 

 

 

Indoor Unit

Outdoor Unit

Complete Unit

 

 

 

 

 

 

 

 

 

 

 

 

Fan Motor

Fan Motor + Compressor

 

 

 

 

 

 

 

 

 

 

 

 

 

Performance at

 

 

 

 

230V Single-phase 60Hz

 

 

 

 

 

 

 

 

Rating conditions

 

Running amp.

A

0.3

6.7

7.0

 

 

 

 

 

 

 

 

 

 

 

Power input

W

32

1,468

1,500

 

 

 

 

 

 

 

Rating conditions:

Indoor air temperature:

80°F (26.7°C) D.B. / 67°F (19.4°C) W.B.

 

 

 

Outdoor air temperature:

95°F (35°C) D.B.

 

 

Cooling

 

 

 

 

 

 

< 208V >

 

 

 

 

 

 

 

 

 

 

 

 

Indoor Unit

Outdoor Unit

Complete Unit

 

 

 

 

 

 

 

 

 

 

 

 

Fan Motor

Fan Motor + Compressor

 

 

 

 

 

 

 

 

 

 

 

 

 

Performance at

 

 

 

 

208V Single-phase 60Hz

 

 

 

 

 

 

 

 

Rating conditions

 

Running amp.

A

0.3

7.4

7.7

 

 

 

Power input

W

32

1,468

1,500

Rating conditions:

Indoor air temperature:

80°F (26.7°C) D.B. / 67°F (19.4°C) W.B.

 

 

 

Outdoor air temperature:

95°F (35°C) D.B.

 

 

Indoor Unit

KS1872

 

 

 

 

Outdoor Unit

CL1872

 

 

 

 

Cooling

 

 

 

 

 

 

< 230V >

 

 

 

 

 

Indoor Unit

Outdoor Unit

Complete Unit

 

 

 

 

 

 

 

 

 

 

 

 

Fan Motor

Fan Motor + Compressor

 

 

 

 

 

 

 

 

 

 

 

 

 

Performance at

 

 

 

 

230V Single-phase 60Hz

 

 

 

 

 

 

 

 

Rating conditions

 

Running amp.

A

0.3

6.7

7.0

 

 

 

Power input

W

32

1,468

1,500

Rating conditions:

Indoor air temperature:

80°F (26.7°C) D.B. / 67°F (19.4°C) W.B.

 

 

 

Outdoor air temperature:

95°F (35°C) D.B.

 

 

Cooling

 

 

 

 

 

 

< 208V >

 

 

 

 

 

Indoor Unit

Outdoor Unit

Complete Unit

 

 

 

 

 

 

 

 

 

 

 

 

Fan Motor

Fan Motor + Compressor

 

 

 

 

 

 

 

 

 

 

 

 

 

Performance at

 

 

 

 

208V Single-phase 60Hz

 

 

 

 

 

 

 

 

Rating conditions

 

Running amp.

A

0.3

7.4

7.7

 

 

 

Power input

W

32

1,468

1,500

Rating conditions:

Indoor air temperature:

80°F (26.7°C) D.B. / 67°F (19.4°C) W.B.

 

 

 

Outdoor air temperature:

95°F (35°C) D.B.

 

 

31

Page 31
Image 31