Recording settings
HAlarm operation settings menu description
This menu is used to extend the duration of the alarm recording and to set the display method when an alarm occurs.
|
|
|
|
| <ALARM OPERATION SET> | |
1 |
|
| ALARM RETRIGGER | : OFF | ||
|
| |||||
2 |
|
| MAIN MON. DISPLAY | : FULL | ||
|
| |||||
3 |
|
|
| ALARM | PRIORITY | : LAST |
|
|
| ||||
4 |
| MON.2 | DISPLAY | : NC | ||
|
(2)If another channel detects a second alarm during DURATION operation and the same channel detects a third alarm, the first alarm recording finishes when the third alarm is detected and the third alarm recording starts. If another alarm is detected on another channel (CH5), the recording takes place as set in DURATION.
1st Alarm detected 3rd Alarm detected
CH1 |
| ALARM NO. 1 | |
|
|
| |
|
| DURATION |
|
|
| 2nd Alarm detected |
1ALARM RETRIGGER
This setting controls whether the recording duration will be extended when another alarm is detected on the same channel that is currently performing alarm recording.
ON:
(1)If a second alarm is detected during DURATION operation on the same channel the recording time is prolonged by the number of minutes set in DURATION from the point when the second alarm was detected.
1st Alarm detected | 2nd Alarm detected | |
|
|
|
CH1 |
| ALARM NO. 1 |
DURATION
(2)If another channel detects a second alarm during DURATION operation and the same channel detects a third alarm the first alarm recording finishes when the third alarm is detected and the third alarm recording starts. If the alarm is detected on another channel (CH5), the recording takes place as set in DURATION.
1st Alarm detected 3rd Alarm detected
CH1 |
| ALARM NO. 1 | ALARM NO. 3 | |||||
|
|
|
|
|
|
| ||
|
| DURATION |
|
|
|
|
| |
|
| 2nd Alarm detected |
|
|
| |||
|
|
|
|
|
|
|
| |
CH5 |
|
| ALARM NO. 2 |
|
|
OFF:
(1)Within the set DURATION, alarms detected by the same channel are not acknowledged, therefore the recording stops at the end of the DURATION. However, the second alarm recording is recorded in the first alarm recording.
1st Alarm detected | 2nd Alarm detected | ||
CH1 |
|
| |
| ALARM | NO. 1 |
DURATION
CH5 | ALARM NO. 2 |
2MAIN MON. DISPLAY
Selects the screen type to use for display when an alarm is detected.
NC: The main monitor will not change, even if an alarm is detected.
FULL: When an alarm is detected, the main monitor will display the video from that channel in
9:When an alarm is detected, the main monitor will change to
16:When an alarm is detected, the main monitor will change to
3ALARM PRIORITY (display when multiple alarms are detected)
Sets the priority for alarm display to use when multiple alarms are overlapping.
LAST: When multiple alarms are overlapping, display is performed in the priority order. The most recent alarm is given first priority, then the one detected before that, and so on.
FIRST: When multiple alarms are overlapping, only the alarm detected first will be displayed. Alarms detected after that will not be displayed.
However, if the duration of the first alarm is over, alarms that have remaining durations will be displayed in the order of detection.
SWITCH: When multiple alarms are overlapping, the alarms will be displayed in a scrolling fashion, showing each alarm video for one second.
4MON. 2 DISPLAY
Selects whether the monitor connected to the MON2 terminal will be used to display the alarm video.
NC: When an alarm is detected, the alarm video will not be displayed on monitor 2.
SWITCH: When multiple alarms are overlapping, the alarms will be displayed in a scrolling fashion, showing each alarm video for one second.
LAST: When multiple alarms are overlapping, display is performed in the priority order. The most recent alarm is given first priority, then the one detected before that, and so on.
FIRST: When multiple alarms are overlapping, only the alarm detected first will be displayed. Alarms detected after that will not be displayed.
However, if the duration of the first alarm is over, alarms that have remaining durations will be displayed in the order of detection.