General settings

GCamera control settings

English

The protocol (address) and the external alarm trigger control settings are needed when operating the coaxial superimposed dome camera.

If the protocol settings are set to "OFF" the "ALARM REC TRIGGER SET" cannot be set.

1Connect the VIDEO IN terminal on the rear panel of the DVR to a remotely controllable dome camera using a coaxial cable. (Figure 1)

2Display the <CAMERA CONTROL SET> screen as explained in "Displaying the general settings screen" (P62).

MENU

<MAIN MENU>

 

 

3.GENERAL SET

 

<GENERAL SET>

 

7.CAMERA CONTROL SET

(J)(S)

 

<CAMERA CONTROL SET>

 

 

 

 

1.

PROTOCOL/ADDRESS SET

->

2.

ALARM REC TRIGGER SET

->

3Turn the J-dial to select "PROTOCOL/ADDRESS SET" and then turn the S-dial clockwise.

The <PROTOCOL/ADDRESS SET> screen is displayed.

 

 

<PROTOCOL/ADDRESS SET>

 

CH PROTOCOL

ADD.

CH PROTOCOL

ADD.

01

OFF

---

 

09

OFF

---

02

OFF

---

 

10

OFF

---

03

OFF

---

 

11

OFF

---

04

OFF

---

 

12

OFF

---

05

OFF

---

 

13

OFF

---

06

OFF

---

 

14

OFF

---

07

OFF

---

 

15

OFF

---

08

OFF

---

 

16

OFF

---

4Turn the J-dial to move the cursor to the channel number (example: 06) of the VIDEO IN terminal where the camera is connected to the rear panel of the DVR, and then turn the S-dial clockwise.

The "OFF" starts blinking.

06 OFF

---

5Turn the J-dial to select the PROTOCOL setting (example: SANYO COAX1), and then turn the S-dial clockwise.

The address (ADD.) is preset, it cannot be modified. Refer to "List of camera addresses" for more information. (P90)

Selections:

OFF: No camera control

SANYO COAX1:

Camera control by coaxial superimposition of the SANYO (SSP) protocol.

The address is automatically displayed.

SANYO RS485:

Camera control by SANYO (SSP) protocol using RS485.

The address is automatically displayed.

BBV COAX:

Camera control by coaxial superimposition of the BBV protocol.

PELCO COAX:

Camera control by coaxial superimposition of the PELCO protocol.

SANYO COAX2:

Camera control by high-speed coaxial superimposition.

06 SANYO COAX1 006

6Press the EXIT/OSD button.

EXIT/OSD

7Press the FUNC. button.

The indicator on the FUNC. button and the control indicators turn on. (P73)

Press the FUNC. button again to exit the function control.

FUNC.

Third-party cameras controlled by RS485, RS422 etc. are not supported. Consult with the store where you purchased your system regarding the types of cameras that are supported.

In order to prevent control mistakes, set the PROTOCOL setting to "OFF" for channels with cameras that are not capable of coaxial superimposition or not of the supported types.

Figure 1

Dome camera (sold separately)

71 How to set