Dimensions

(Module type : HIP-xxxNHE5, -xxxNHE5-BO2,


with connector and cable)

Section B-B’

Section A-A’

dimensions in mm

SideFront Backside

Figure2-1 : Dimension

Mounting Places
(4 places)
Label
Junction
Box
positive(+)
negative(-)
4󲦸󲍃7
Connector (MC Plug)
5Printed in Europe 20.10.2006
DIODES

Bypass Diodes

When the modules in series strings
are shaded partially, it may cause a
reverse
󲣮
voltage
󲣮
across
󲣮
cells
󲣮
or
modules, because the current from
other
󲣮
cells
󲣮
in the same series is
forced to flow through the shaded
area, and then undesirable heating
may occur.
󲣮
The use of a diode to
bypass
󲣮
the
󲣮
shaded
󲣮
area
󲣮
can
minimize both heating and reduction
of array current.
All SANYO modules are equipped
with factory installed bypass diodes.
The factory-installed diodes provide
proper circuit protection for the
systems within the specified system
voltage, so that you don’t need
any other additional bypass diodes.
Contact your authorized SANYO
distributor or dealer for proper diode
type, if necessary to add or change
diodes due to system specification.
MAINTENANCE
Some maintenance is recommended to maintain optimal output performance of solar cell modules. If the module
surface becomes dirty, it may cause reduction of output power. It is recommended to clean the surface with
water and soft cloth or sponge. A mild non-abrasive detergent may be applied for the persistent dirt. And it is also
recommended to inspect the electrical and mechanical connections annually.
If you need electrical and mechanical inspection or maintenance, it is recommended to have the authorized
professional carry out the inspection or maintenance to avoid the hazards of electric shock or injury.
󲇨󲆊
Note : In case of installation on a rail structure, module must be attached
within the depicted shaded range.
󲆊󲆎󲆈
󲆌󲆎󲆈
󲆊󲆎󲆈
󲆌󲆎󲆈