01_KS3682_EN.fm Page 4 Friday, February 12, 2010 12:26 PM

NAMES OF PARTS

Air intakes

INDOOR UNIT

Air outlet

Remote control unit

Drain hose

Refrigerant tubes

OUTDOOR UNIT

Air outlet

NOTE

This illustration is based on the external view of a standard model. Consequently, the shape may differ from that of the air conditioner which you have selected.

This air conditioner consists of an indoor unit and an outdoor unit. You can control the air conditioner with the remote control unit.

Air Intake

Air from the room is drawn into this section and

 

passes through air filters which remove dust.

 

 

Air Outlet

Conditioned air is blown out of the air

 

conditioner through the air outlet.

 

 

Remote

The wireless remote control unit controls power

Control Unit

ON/OFF, operation mode selection,

 

temperature, fan speed, timer setting, and air

 

sweeping.

 

 

Refrigerant

The indoor and outdoor units are connected by

Tubes

copper tubes through which refrigerant gas

 

flows.

 

 

Drain Hose

Moisture in the room condenses and drains off

 

through this hose.

 

 

Outdoor

The outdoor unit contains the compressor, fan

(Condensing)

motor, heat exchanger coil, and other electrical

Unit

components.

 

 

 

UNIT DISPLAY AND OPERATION BUTTON

INDOOR UNIT

OPERATION lamp

TIMER lamp

REMOTE CONTROL receiver

OPERATION button LED CLEAN lamp (ON/OFF)

IMPORTANT

Avoid using radio equipment such as mobile phone near (within 4 ft. (1.2 m)) the remote control receiver. Some radio equipment may cause malfunction of the unit.

If the trouble happens, disconnect power and restart the air conditioner after a few minutes.

REMOTE

This section picks up infrared signals from the

CONTROL

remote control unit (transmitter).

 

receiver

 

 

 

 

 

 

OPERATION

When the remote control unit cannot be used,

button

pressing this button enables cooling operation.

 

Each time this button is pressed, the operation

 

mode changes cyclically.

 

 

Cooling operation

 

Stop

 

 

 

 

 

OPERATION

This lamp lights when the system is in the

lamp

continuous DRY (orange), COOL (green) and

 

FAN (green) mode.

 

 

 

 

TIMER lamp

This lamp lights when the system is being

 

controlled by the timer.

 

 

 

 

LED CLEAN

This lamp lights during operation in the UV anti-

lamp

bacterial mode.

 

 

 

 

 

NOTE

The unit’s display lamps are dimmed during operation in the NIGHT SETBACK mode.

4

OI-150-4-EG

 

Page 4
Image 4
Sanyo KS3682, KS3082 instruction manual Names of Parts, Unit Display and Operation Button