INSTALLATION SITE

To operate this unit properly and to obtain maximum performance, install the unit in a location with the following conditions:

A location not subjected to direct sunlight

Do not install the unit under direct sunlight. Installation in a location subjected to direct sunlight cannot obtain the intended performance.

A location with adequate ventilation

Leave at least 10 cm around the unit for ventilation. Poor ventilation will result in a reduction of the performance and consequently the failure.

A location away from heat generating sources

Avoid installing the unit near heat-emitting appliances such as a heater or a boiler etc. Heat can decrease the intended performance of the unit.

A location with little temperature change

Install the unit under stable ambient temperature. The allowable ambient temperature is between +5 and +30oC.

A location with a sturdy and level floor

Always install the unit on a sturdy and level floor. The uneven floor or tilted installation may cause failure or injury. Install the unit in stable condition to avoid the vibration or noise. Unstable condition may cause vibration or noise.

WARNING

Install the unit on a sturdy floor. If the floor is not strong enough or the installation site is not adequate, this may result in injury from the unit falling or tipping over.

Select a level and sturdy floor for installation. This precaution will prevent the unit from tipping. Improper installation may result in water spillage or injury from the unit tipping over.

A location not prone to high humidity

Install the unit in the ambient of 80% R.H. or less humidity. Installation under high humidity may cause current leakage or electric shock.

WARNING

Do not use the unit outdoors. Current leakage or electric shock may result if the unit is exposed to

rain water.

Never install the unit in a humid place or a place where it is likely to be splashed by water.

Deterioration of the insulation may result which could cause current leakage or electric shock.

A location without flammable or corrosive gas

Never install the unit in a flammable or volatile location. This may cause explosion or fire or may result in the current leakage or electric shock by the corrosion of the electrical components.

A location without the possibility of anything fall

Avoid installing the unit in the location where anything can fall down onto the unit. This may cause the breakdown or failure of the unit.

- 53 -

11

Page 12
Image 12
Sanyo MDF-U7486SC, MDF-U5486SC instruction manual Installation Site

MDF-U5486SC, MDF-U5486S, MDF-U7486S, MDF-U7486SC specifications

Sanyo is a renowned brand in the field of refrigeration and climate control solutions, and its MDF series of laboratory freezers is a testament to its commitment to quality and innovation. The models MDF-U7486SC, MDF-U5486SC, MDF-U7486S, and MDF-U5486S are designed to provide optimal cold storage solutions for sensitive materials in laboratories, clinics, and research facilities.

The MDF-U7486SC and MDF-U5486SC models stand out with their superior temperature stability and precision. Both units feature a microprocessor control system that offers precise temperature regulation, ensuring that stored samples remain within the desired specifications. The cooling system utilizes advanced compressor technology, which enhances energy efficiency while maintaining a low noise operation, making them ideal for quiet laboratory environments.

With a storage capacity of 740 liters for the MDF-U7486SC and 540 liters for the MDF-U5486SC, these freezers provide ample space for large quantities of biological and pharmaceutical materials. The interiors are designed with adjustable shelving, allowing for flexible organization of samples and easy access.

In terms of security, these models come equipped with a comprehensive alarm system that alerts users to deviations in temperature and power failures. The built-in data logger feature records temperature changes, providing a crucial audit trail for compliance and quality assurance.

On the other hand, the MDF-U7486S and MDF-U5486S models offer similar benefits but cater to slightly different needs. The S versions emphasize energy efficiency coupled with a robust cooling performance. They are designed to minimize energy consumption while still delivering reliable cold storage solutions. With an easy-to-use control panel, users can quickly adjust settings and monitor performance, ensuring optimal operation.

All models are constructed with high-quality materials, including a durable exterior that can withstand the rigors of laboratory environments. The insulation is of premium quality, which contributes to maintaining stable internal temperatures while minimizing energy loss.

In conclusion, Sanyo's MDF-U7486SC, MDF-U5486SC, MDF-U7486S, and MDF-U5486S freezers are excellent choices for laboratories looking for reliable, efficient, and secure cold storage solutions. With advanced technologies, robust performance, and user-friendly features, these models meet the diverse needs of scientific research and medical storage while ensuring sample integrity and safety.