Image 18
Attachment of temperature recorder

TEMPERATURE RECORDER

Attachment of temperature recorder

For refrigerator

1.Attach the fixture to the temperature recorder with two screws. (Fig. 1)

2.Remove the screws at the right corner on the top of the unit and fix the recorder to the position. (Fig. 2)

3.Remove a rubber cap and insulation covering the access hole on the back of the unit.

4.Take the recorder sensor into the refrigerator chamber through the access hole.

5.Fix the recorder sensor on the right wall of the chamber with the enclosed clips (large). (Fig. 3)

6.Make a cut on the rubber cap and route the lead wire through it. (Fig. 4)

7.Cover the access port with the insulation and rubber cap.

For freezer

1.Remove a cap for the fixing screw on the cover for mounting space of temperature recorder.

2.Remove the fixing screw and open the panel. (Fig.

5)

3.Remove the panel by pushing the shaft on both side outward and remove the panel fixture.

4.Attach the temperature recorder (MTR-4014LH) to the recorder fixture [MDF-53RO (H)] by using the enclosed screws. (Fig. 6)

5.Remove a rubber cap and insulation covering the access port on the back of the unit.

6.Take out the recorder sensor from the back of the unit through the mounting space.

7.Pass the sensor through the access port of the freezer. The length of the capillary inside the freezer should be about 40 cm.

8.Fix the recorder sensor on the left wall of the chamber with the enclosed clips (small). (Fig. 7)

9.Make a cut on the rubber cap and route the lead wire through it. (Fig. 4 above)

10.Cover the access port with the insulation and rubber cap.

11.Fix the extra capillary tube to the back of the recorder with the enclosed clip and screw. (Fig. 8)

12.Mount the recorder fixture to the mounting space in the unit. (Fig. 9)