2. Key lock operation

OPERATING INSTRUCTIONS

2. Key lock operation

This unit incorporates a key lock feature which can inhibit the tampering using the keys on the control panel.

The key lock is set to OFF at the factory.

 

Display

Mode

Function

 

 

 

Key lock OFF

Temperature change enabled

 

 

 

Key lock ON

Temperature change disabled

 

Table 2 Key lock setup procedure (Example: Key lock OFF Key lock ON)

 

 

Operation

Key operated

Indication after operation

Display mode

 

 

-----

The current refrigerator or freezer

Temperature

 

 

 

temperature is displayed.

display mode

1

Press and hold the digit shift

The lower digit of the temperature

Key lock

 

key for about 5 seconds

 

display blinks.

mode

2

Set the lower digit to “1” with

Pressing the key shifts up the

 

 

the numeric value shift key

 

figure of the digit.

 

3

Press the set key

 

Key lock is set to ON and the current

Temperature

 

 

SET

refrigerator or freezer temperature is

display mode

 

 

 

displayed.

 

Note:

Key lock can be set any time when the current refrigerator or freezer temperature is displayed.

If the numerical value shift key is held depressed for more than about 5 seconds, F0 is displayed. This is one of the functions used by the service personnel and the figure should not be changed. To return to the refrigerator or freezer temperature display mode, press the set key or leave the unit for about 90 seconds without pressing any key.

13