Image 11
Control panel

REFRIGERATOR COMPONENTS

Control panel

10

9

8

7

6

DOOR

DOOR REFRIGERATOR

Manual backgroundManual background FREEZER

REF.

FREEZ.

1

2

3

4

5

1.Alarm buzzer stop key (BZ): Press this key to silence the buzzer in the event that the alarm operates and buzzer sounds. See page 17 for the details.

2.Display select key (REF./FREEZ.): By pressing this key, chamber temperature display of refrigerator or freezer and each setting is selected.

3.Set key (SET): Pressing this key activates temperature set mode and the digit which can be set is flashed. By pressing the key again after setting, the set value is accepted.

4.Digit shift key ( Manual background ): Pressing this key in set mode causes the changeable digits to move. Key lock is activated by pressing this key for more than 5 seconds in the temperature display mode. See “Key

lock operation” on page 14.

5.Numerical value shift key ( Manual background): Pressing this key in the setting mode causes the numerical value to change. “ON-OFF” of key lock can be selected by pressing this key in the key lock mode.

6.Temperature display: This indicator shows the chamber temperature, set temperature, or error code.

7.Refrigerator indicator (REFRIGERATOR): This indicator is lit when the refrigerator is selected.

8.Freezer indicator (FREEZER): This indicator is lit when the freezer is selected.

9.Alarm lamp (ALARM): This lamp is flashed during alarm condition. Refer to page 15 “Alarm temperature setting”.

10.Door check lamp (DOOR): This lamp is lit when the door is open.

42

 

10

 

Page 11
Image 11