Maintenance and Cleaning
Connect the AC power cord to the projector and turn on the projector.
Turn off the projector and unplug the AC power cord. Let the projector cool for at least 45 minutes.
Turn the projector over. Remove the screw that secures the lamp cover, and then open the lamp cover.
Loosen the two screws that secure the lamp. Lift the lamp out of the projector by using the built in handle.

Maintenance and Cleaning

Lamp Replacement

When the projection lamp of the projector reaches the end of its life, the LAMP REPLACE indicator emits a yellow light. If this indicator lights yellow, replace the lamp with a new one promptly.

WARNING:

TURN OFF THE UV LAMP BEFORE

OPENING THE LAMP COVER

Top Control

This indicator

 

 

turns yellow

 

 

when the

 

 

 

 

projection lamp

 

 

reaches the end

 

 

of its life.

Lamp replacement icon

 

Note:

The Lamp replacement icon will not appear when the Display function is set to “Off” (p.41), during “Freeze” (p.23), or “No show” (p.24).

1 CAUTION

Allow the projector to cool for at least 45 minutes before you open the Lamp cover. The inside of the projector can become very hot.

6 Reset the lamp replacement counter.. CAUTION

For continued safety, replace with a lamp of the same type. Do not drop a lamp or touch a glass bulb! The glass can shatter and may cause injury.

Follow these steps to replace the lamp.

1

2

3

4 Replace the lamp with a new one and secure it with the two screws. Make sure that the lamp is set properly. Put the lamp cover back and secure it with the screw.

5

6 Reset the lamp replacement counter..

See “Lamp Replacement Counter” on the next page.

Lamp Cover

Screw

Lamp Screw

Screw

Handle

ORDER REPLACEMENT LAMP

Replacement lamp can be ordered through your dealer. When ordering a projection lamp, give the following information to the dealer.

Model No.. of your projector : PLC-WXL46

Replacement Lamp Type No.. : POA-LMP106

(Service Parts No. 610 332 3855)