Fan control

This function is used to set the cooling fans’ operation to the projector’s setting environment. Set this function properly in accordance with the projector’s installation method.

Otherwise, the cooling fans will not work properly and that causes malfunctions of the projector and decreases the lamp life.

Slant

Select the projector’s installation condition from the following options:

Off

When using the projector within the range of the

 

upward/ downward inclination of 20 degrees to

 

the horizontal plane.

L1

When using the projector within the range of the

 

upward inclination of over 20 degrees to the

 

horizontal plane.

L2

When using the projector with downward

 

inclination of over 20 degrees to the horizontal

 

plane.

Highland

Set this function according to the ground elevation under which you use the projector. When using the projector in high altitudes (about 1,200 meters or more above the sea level) where the fans have less cooling effect, set this function to “On.”

Security (Key lock and PIN code lock settings)

This function allows you to use the Key lock and PIN code lock function to set the security for the projector operation.

Key lock

This function locks the top control and remote control buttons to prevent operation by unauthorized persons.

...... Unlocked

...... Lock all the top control buttons

...... Lock the top control buttons except for the

ON/STAND-BY, INPUT, and INFO. buttons. To unlock, use the remote control.

...... Lock all the remote control buttons. To

unlock, use the top control.

...... Lock the remote control buttons except

for the ON, STAND-BY, INPUT 1–3, AUTO PC, FREEZE, and INFO. buttons.

If the top control accidentally becomes locked and you do not have the remote control nearby or there is something wrong with your remote control, contact the dealer where you purchased the projector or the service center.

Fan control

Press the SELECT button at Fan control and this dialog box appears. Use the Point ed buttons to choose Slant or Highland. Use the Point 78 buttons to switch between the options.

Key lock

Select Key lock. Use the Point ed buttons to choose one of the options and select [Yes] to activate it.