– 40 – SM830079
11. SERVICE PROCEDURES
(2) A Sensor is Defective
11
11
1Indoor (heat exchanger) coil temp. Sensor is defective.
(a) Open (=No continuity in sensor)
Compressor and outdoor fan repeat ON for 10 minutes and OFF for 6 minutes
when sensor opens.
(b) Short
“Freeze Prevention” does not operate when dehumidified water is frozen on the
indoor coil.
22
22
2Room temp. Sensor (in the remote control unit) is defective.
(a) Open (=No continuity in sensor)
Neither outdoor fan nor compressor runs.
(b) Short
Outdoor fan and compressor do not stop. — Excessive cooling.
(3) Operation of Major Electrical Parts
Oudoor unit
Fan Compressor
Manual Thermo.ON VV VV V
Thermo.OFF VV V
Night Thermo.ON VV V VV V
setback Thermo.OFF VV V
Timaer ON Timer V
(set) OFF Timer VVV VV V
Freeze prevention VV V
VV
Sweep Cool VV*V*VV*V*
Fan VV
Stop Cool VV*V*VV*V*
Fan VV
NOTE V* Refer to Cooling Mode.
Indicator lamps
Cool
Room
Temp.
(Function)
Operation Mode Operation Indoor unit and Remote Control unit
Sweep
Fan
Night setback
Energy saver
Timer
Cool
-ing
Fan
Flap