EZ Manual: M-8400RVe

3

 

 

 

 

Electric Checks and Adjustments

 

 

 

 

Chart 1

 

 

 

 

 

 

 

 

Dial test point

Comment

Voltage

Voltage Range

Check pin on TP Test Module and Main PCB

 

Adjustment to VR

 

 

 

 

 

 

 

0

DC power Supply

+5.0 VDC

+4.8V to +5.2V

CH3A(+5.0V) - CH1A(GND)

 

N/A

 

 

 

 

 

 

 

1

DC power Supply

+2.0 VDC

+1.9V to +2.1V

CH4A(+2.0V) - CH1A(GND)

 

N/A

 

 

 

 

 

 

 

2

DC power Supply

+3.3 VDC

+3.1V to +3.5V

CH5A(+3.3V) - CH1A(GND)

 

N/A

 

 

 

 

 

 

 

3

DC power Supply

+24.0 VDC

+23.5V to +24.5V

CH6A(+24.0V) - CH1A(GND)

 

N/A

 

 

 

 

 

 

 

 

 

Low level (Set the blank area

 

 

 

 

 

on the sensor) = A

 

 

 

 

 

 

 

 

 

4

I-Mark Sensor Level

High level (Set the I-mark

CH1B(+8.4V) - CH1A(GND)

 

VR5

on the sensor) = B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

High level - Low level =

 

 

 

 

 

A - B = more than +0.9V

 

 

 

 

 

 

 

 

 

 

 

 

Low level (Set the label backing liner or the

 

 

 

 

 

centre hole [in case of the centre hole tag]

 

 

 

 

 

on the sensor) = C

 

 

 

5

Gap sensor Level

High level (Set the label or

CH2B - CH1A(GND)

 

VR4

tag on the sensor) = D

 

 

 

 

 

 

 

 

 

High level - Low level =

 

 

 

 

 

C - D = more than +1.0V

 

 

 

 

 

 

 

 

 

 

< previous home next >

Barcode SATO International Pte Ltd

Page 3
Image 3
SATO 8400RVe manual Chart, Mark Sensor Level