SATO CX200 manual Communication Ports, Serial Input Connector DB9S, Standard Printer Cables

Models: CX200

1 24
Download 24 pages 583 b
Page 22
Image 22
Communication Ports

CX200 User's Guide

Communication Ports

CX200 printers are equipped with Centronics parallel and RS232C commu- nication ports, wired as shown below.

Serial Input Connector (DB9S)

Pin #

Description

 

 

2

RXD (data to printer))

3

TXD (data from

printert)

 

5

Ground

7

RTS (printer busy)

8

CTS

1, 9

+5VDC, 200 mA max.

 

 

Parallel Input Connector (Centronics 36 pin)

 

Pin #

Description

 

 

 

 

1

Strobe

 

2-9

Data bits 0-7

 

10

Acknowledge

 

11

Busy

 

12

Out of Paper

 

13

+5DC

 

17

Chassis Ground

 

31

Reset

 

32

+5VDC

 

16, 33

Signal Ground

 

19-30

 

 

 

 

 

Standard Printer Cables

 

The following standard cables are available for CX200 printers:

Centronics Parallel Cable, 6 ft.:

Order PN 14S000132

RS232 Cable, DB9M to DB9F, 6 ft.:

Order PN 14S000133

RS232 Cable, DB9M to DB25F, 6 ft.:

Order PN 14S000134

Serial Port Parameters

CX200 printers are configured as Data Terminal Equipment (DTE) equip- ment, and use Request-To-Send/Clear-To-Send (RTS/CTS) handshaking or XOn/X-Off flow control (control characters are DC2 and DC4). The serial port supports the following parameters:

Speed:

600, 1200, 2400, 4800, 9600, or 19200 Baud

Parity:

Odd, Even, or None

Data Bits:

7 or 8 bits

Stop Bit(s):

1 or 2 bits

Default parameters: 9600 baud, no parity, 8 data bits, 1 stop bit