Multi Room Audio Amplifier

Installation Instructions

2 Installation

This document covers the standalone audio amplifier installation without a matrix switcher. Installing multiple amplifiers is discussed in this document. If you need additional details about the amplifier's features or connections, refer to the MRA system-level documents listed previously.

2.1Installation Steps

The following table gives you an overview of the installation process flow.

Step

Description

Read safety information

Make sure you understand the critical safety and product

 

handling information and gather product documentation

 

before you start. Sections 1.2, 1.3, 1.4.

 

 

Plan the installation

Select a convenient location for the amplifier and the

 

speakers. Determine which C-Bus input units will control

 

the amplifier. Locate a wall power outlet for the power

 

supply. Consider the placement and connection of audio

 

source equipment. Section 2.2.

 

 

Configure with software

Use Toolkit to modify the C-Bus network configuration to

tools

add the amplifier and set up its relationship with C-Bus

 

input units. If you are using a C-Touch touchscreen, use

 

PICED software to set up the interface.

 

 

Pre-wire

Install the C-Bus network, speakers and audio source

 

cabling. If you are connecting two or more amplifiers,

 

install Digital Audio cables as well.

 

 

Install the physical units

Install the amplifier, speakers and power supply. Then

 

connect the required cables.

 

 

Apply power

Check all wiring and plug the power supply in to the wall

 

power outlet.

 

 

Table 3. Installation steps

 

7

Page 7
Image 7
Schneider Electric 560125D/2, 560110R, 560125R/2 installation instructions Installation Steps, Step Description

560125R/2, 560110R, 560125D/2 specifications

Schneider Electric stands as a leader in energy management and automation solutions, providing innovative products that maximize efficiency and sustainability. Among its extensive portfolio, the Schneider Electric 560125D/2, 560110R, and 560125R/2 models are noteworthy for their advanced features and technologies designed for a variety of applications.

The Schneider Electric 560125D/2 model is a high-performance device engineered for efficient energy management. It incorporates a modular design that allows for flexible configuration options, making it suitable for a wide range of industrial and commercial applications. One of its main features is its advanced monitoring capabilities, enabling users to track energy consumption in real time. This helps in identifying inefficiencies and facilitating data-driven decision-making aimed at reducing operational costs.

The 560110R model features state-of-the-art communication technologies, including Modbus and Ethernet connectivity. This facilitates seamless integration with existing systems and allows for remote monitoring and management. The device's user-friendly interface provides easy access to vital information through a clear and intuitive display, making it simple for operators to manage energy use and optimize performance. The robust construction of the 560110R ensures durability in demanding environments, reinforcing its reliability across various sectors.

Meanwhile, the Schneider Electric 560125R/2 further enhances the capabilities found in its counterparts. It is designed for scalability, making it ideal for businesses that anticipate growth and expansion. This model supports multiple input and output options, enabling comprehensive control over various equipment and systems. Additionally, its software tools provide insightful analytics, empowering users to implement effective energy-saving strategies and improve overall system efficiency.

Each of these models is equipped with Schneider Electric's innovative EcoStruxure technology, which promotes IoT-enabled solutions for greater visibility and control of energy assets. This transformative technology enhances performance and promotes sustainability by providing actionable insights into energy use and operational efficiency.

In conclusion, Schneider Electric's 560125D/2, 560110R, and 560125R/2 models reflect the company's commitment to driving efficiency and sustainability in energy management. With their advanced features, robust performance, and easy integration capabilities, these devices are exemplary solutions for modern industrial and commercial energy challenges.